Maintenance, Nspection, Chedule – Wood’s Powr-Grip EO3VLW User Manual

Page 8

Advertising
background image

Rev 9.0/9-13

6

EO3VLW: #35193AFT

MAINTENANCE

I

NSPECTION

S

CHEDULE

Perform inspections of the Vacuum Loss Warning Buzzer routinely, according to the following

frequency schedule:

Frequent Inspection

(

following every 20-40 hours’ use; or whenever Warning Buzzer is out of service for 1 month or more

)

• Test the battery strength (see B

ATTERY

T

EST

to follow)

• Examine the in-line filter connected to the Warning Buzzer to make sure its desiccant has not

been expended: The desiccant shows a

blue

coloration when new and turns progressively

more

pink

as it absorbs moisture. When the desiccant is no longer effective, the filter must

be replaced (see REPLACEMENT PARTS LIST).

• Test the Warning Buzzer for proper function (see OPERATION).
If any deficiency is detected during the inspection, correct it before using the Warning Buzzer,

and perform the Periodic Inspection to follow.

Periodic Inspection

(

following every 250-500 hours’ use; or whenever Warning Buzzer is out of service for 1 year or more

)

• Test the vacuum setting (see V

ACUUM

S

ETTING

A

DJUSTMENT

to follow).

• Keep a written record of all Periodic Inspections.
If any deficiency is detected during the inspection, adjust the vacuum setting as directed under

V

ACUUM

S

ETTING

A

DJUSTMENT

to follow.

Infrequent Use

If the Warning Buzzer is used less than 1 day in a 2-week period, perform the Periodic Inspection

each time before using the Warning Buzzer

.