Accessories, Cordsets and accessories, Data byte 1 – Rockwell Automation 42EF RightSight DeviceNet Photoelectric Sensors User Manual

Page 3: Straight bracket #60 6 apertures, Right angle bracket #60 7, Swivel/tilt bracket #60 9

Advertising
background image

3

10_Adjustment in

Each Direction

30_

15.7

(0.62)

14.3

(0.75)

R 24

(0.95)

52

(2.04)

2 Plc

70

(2.78)

Accessories

Straight Bracket #60--2656

Apertures

(Transmitted Beam Only)

Right Angle Bracket #60--2657

15

(0.059)

Ref

42.4

(1.67)

R 15

(0.59)

15.7

(0.62)

30_

3 Places

018.5

(0.728)

29

(1.143)

12.7

(0.50)

53

(2.10)

35.8

(1.41)

1.5

(0.059)

Ref

42.4

(1.67)

12.7

(0.50)

29

(1.143)

R 24

(0.95)

18.5 (0.728)

Note: 18mm nut must be installed

prior to installing aperture if threads

on optics snout are to be used.

4.6

(0.181) 4 Plc

4.6

(0.181)

4 Plc

35.8

(1.41)

3 Plc

Swivel/Tilt Bracket #60--2649

15.7

(0.62)

57.15

(2.25)

28.6

(1.125)

50.08

(2.0)

7.95

(0.31)

1mm Qty. 20 #60- 2660

2mm Qty. 20 #60- 2661

4mm Qty. 20 #60- 2662

Aperture Set (4 each) #60- 2659

90_

Cordsets and Accessories

Description

Catalog Number

2m (6.5ft) micro QD Cordset

1485R--P2R5--C

2m (6.5ft) micro QD Patchcord

1485R--P2R5--F5

RS--232 PC Interface Module

1770--KFD

DeviceNet Manager Software

1787--MGR

PCMCIA DeviceNet Interface Card

1784--PCD

DeviceNet Hand-Held Configurator

2707--DNC

Reflector, 3I Diameter

92--39

Reflector, 1.5I Diameter

92--47

Other DeviceNet Products

See Pub. DN--2.5

Data Byte 1

Bit 0

Bit 1

Bit 2

Bit 3

Bit 4

Bit 5

Bit 6

Bit 7

Output

Diagnostic

Margin 1

Margin 2

Motion Detect

Counter Output

Not Used

Not Used

0

OFF

OK

OK

OK

Motion

Less Than Preset

1

ON

ALARM

Margin Unstable

Margin Unstable

No Motion

Preset Reached

Target

Note

: Due to the detection method, targets traveling horizontal to

the sensor’s optics are detected. Targets traveling vertically may

not be accurately detected. For reliable background suppression,

a minimum separation distance of 6mm (0.24in) is recommended

between the target and the backgrounds.

Background Suppression Sensors

Glass Fiber Optic Sensors

Sensitivity Adjustment

Retaining

Clip

Groove in end tip

Note

: RightSight fiber optic

models require Series C

glass fiber optic cables

with retaining grooves in

the control end tips.

Advertising