Mx14 – Rockwell Automation 160 Configured Drive Package-160 SSC Ser C User Manual

Page 44

Advertising
background image

44

MX14

*

LOCAL

REMOTE

(OX)

DEVICE

2-WIRE

*

LOCAL

REMOTE

(OX)

DEVICE

2-WIRE

1-3

1C

1-2

1-3

1C

1-2

*

*

11

10

9

OUTPUTS

PROGRAMMABLE RELAY

COMMON

RUN FORWARD

TB3/KEYPAD OR COMMUNICATION CONTROL

8

6

7

160

TB3

WIPER/0-10VDC INPUT

TERMINAL BLOCK TB3

CONTROL BOARD

RUN REVERSE

4-20mA INPUT

5

4

COMMON

+10V POT

2

3

1

INPUT MODE 6

(PAR 46 = 6)

ANALOG SIGNAL FOLLOWER

TB3/KEYPAD OR COMMUNICATION CONTROL

PROGRAMMABLE RELAY
OUTPUTS

TERMINAL BLOCK TB3

PRESET SPEED MODEL

SW3

CONTROL BOARD

SW2

11

10

9

RUN FORWARD

COMMON

8

7

6

TB3

RUN REVERSE

5

4

SW1

COMMON

2

3

1

(PAR 46 = 6)

INPUT MODE 6

160

10

11

9

8

7

6

4

5

3

TB3

1

2

11

10

9

8

7

6

TB3

5

4

2

3

1

01

12-17-99

ARS

99P0562

02

02-18-00

ARS

00P0044

03

06-16-00

ARS

00P0291

04

01-19-01

ARS

01P0009

C-300358-2

WS\STD\300358\02-17

17

18

SCHEMA

TIC,

BULLETIN 160 A

C DRIVE SERIES C

C

ONTROL L

OGIC OPTION MX14

PROJECT

: DRIVE

24VDC INPUT INTERF

A

CE

AC
A

D

12-17-99

ARS

12-17-99

BAH

12-17-99

L\DM\1336P??

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

A

B

C

D

E

F

G

H

40

41

39

38

37

36

35

28

33

34

32

31

30

29

27

26

25

24

23

22

14

20

19

18

17

16

15

13

12

11

9

10

8

7

6

5

4

2

3

1

21

28

31

30

29

27

26

25

24

23

22

14

20

19

18

17

16

15

13

12

11

9

10

8

7

6

5

4

2

3

1

32

INDEX NO

.

REFERENCE D

WG.

DA
TE

APP'D

DA
TE

DA
TE

DR.

TITLE:

DW

G

.

NO
.

RE
V

.

DA
TE

ECN NUMBER

LEAD ENG.

SH:

SH:

NEX

T

BY

THIS DR

A

WING IS

THE PROPERT

Y OF

ROCK

WELL A

UT
OMA

TION,

INC.

OR IT

S

SUBSIDIARIES AND MA

Y NO

T BE C

OPIED

,

USED OR DISCL

OSED FOR ANY PURPOSE

EX
CEPT AS A

UTHORIZED IN

WRITING BY

ROCK

WELL A

UT
OMA

TION,

INC.

LAMINA

TED DRA

WING MUST BE RE-ISSUED

T

O SHOP AFTER ECN

24VDC

INTERFACE

INTERFACE

24VDC

AND PROTECTED 24VDC

+

CUSTOMER SUPPLIED

-

AND PROTECTED 24VDC

+

CUSTOMER SUPPLIED

-

24VDC

FROM

1-19

31

MX14 OPTION

MX14 OPTION

24VDC

1-19

FROM

31

CONNECT THE -24VDC & +24VDC TO TERMINALS TB3-7 & TB3-8 RESPECTIVELY WHEN
D13, D33 OR MX12 ARE NOT ORDERED.

NOTE 1:

WTS277

\ 0001

30

32

A2

A1

30

32

A2

A1

NOTE 2:

NOTE 2:

NOTE 2: CONNECT TERMINAL 7 TO ENCLOSURE GROUND WHEN EMC OPTION IS PRESENT.

Advertising