Specifications

Guardmaster EtherNet/IP Network Interface

Attribute

Value

Safety classification value

• Not applicable. This product is not intended for

safety-related control or diagnostics.

Guardmaster Safety Relay capacity • 6 Guardmaster safety relays

Supported modules (FW Rev 2.xx
or greater)

• GSR DI (Catalog number 440R-D22R2)
• GSR DIS (Catalog number 440R-D22S2)
• GSR EM (Catalog number 440R-EM4RR2)
• GSR EMD (Catalog number 440R-EM4R2D)
• GSR GLP (Catalog number 440R-GL2S2P)
• GSR GLT (Catalog number 440R-GL2S2T)

Location

Left side of the Guardmaster Safety Relay system

Power Supply

Attribute

Value

Input voltage rating

24V DC

Input voltage, range

11...26.4V DC

Input overvoltage protection

Reverse polarity protected

Ethernet Communication

Attribute

Value

Ethernet communication rate

10/100 Mbits/s, half or full-duplex

Ethernet ports

2, configured as Embedded Switch

Ethernet network topologies
supported

Star, Tree, Daisy-chain/Linear, and Ring

Ethernet connectors

RJ-45, Category 5

Ethernet cable

Category 5:

shielded or un-shielded

Ethernet wire connections, max.

See Wire size on page 17