1 import a components list generated with mcs star – Rockwell Automation 141A Mounting System Temperature Rise Calculation Software Tutorial User Manual

Page 12

Advertising
background image

10

Next,

select the [ Evaluate ] button.

2.3.1
Import a
Components List
Generated with
MCS Star

In the window

“Evaluate Dissipation for Enclosure 1”

select [ Import MCS Star ]

Enter or select the fi lename of the DBF fi le you have exported before from MCS Star

Select the [ Import ] button

Note:

TRCS does a look-up in the Rockwell Automation Components database. Th

e power-loss

data for all components are stored there as follows:

P

0

Constant losses (e.g. power supply, contactor coils)

P

1

Losses proportional to the current (~ I; e.g. power semi-conductors)

P

2

Losses proportional to the square of the current (~ I

2

; e.g. conductors, fuses,

contact systems)

I

ref

Reference current for P

1

and P

2

(current where P

1

or P

2

occur)

Advertising