#00658.0000

#00831.0000

29707.1 082803

When re-wiring the machine for operation on

120/208V or 120/240V, the replacement Power

Supply Cord must be UL Listed Flexible Cord Type

SO, SJO, SJTO, HSJO or SJOW, No. 12 AWG, 4

Conductor, Rated 90

° C. Attachment Plug Cap

must be UL Listed, NEMA 14-20P or L14-20P

Configuration, Rated 125/250V, 20 AMPS. The

Power Supply Cord must be at least 3 feet long

and maximum 6 feet long (measured from Strain

Relief to end of the Attachment Plug Cap.)

!

CAUTION

#34072.0000

USER NOTICES

Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should
be kept in good condition. Replace any unreadable or damaged labels.

#29710.0005 (3 Warmers)

CDBC(F)-DV BREWERS

Optional Field Wiring

120 V, 15.0 A, 1800 W

1PH, 2-Wire, 60HZ

Optional Field Wiring

120/208-240 V, 15.6-17.5 A, 2980-3850 W

1PH, 3-Wire, 60HZ

#29710.0007 (3 Warmers)

CDBC(F)-DV BREWERS

Optional Field Wiring

120/208-240 V, 13.0-15.0 A, 2680-3550 W

1PH, 3-Wire, 60HZ

#29710.0008

CDBC(F) APS-DV & TC-DV

BREWERS

#29710.0006 (No Warmer)

CDBC(F) APS-DV BREWERS

Optional Field Wiring

120 V, 12.5 A, 1500 W

1PH, 2-Wire, 60HZ