Summary of parameter changes – Rockwell Automation 160 160 Ser C Custom Firmware P04, FRN 7.06, A005 User Manual

Page 3

Advertising
background image

160 Series C Custom Firmware

3

Summary of
Parameter Changes

The following parameter changes have been made to the standard 160 Preset
Speed firmware version 7.06 drive.

Parameter
Number

Standard Preset Speed
Drive Parameter Name

Custom Firmware Change

30

Accel Time 1

Default changed to 5.0 sec

31

Decel Time 1

Default changed to 5.0 sec

32

Minimum Frequency

Default changed to 6 hz

46

Input Mode

Input modes “4” and “5” modified (see pages 1 & 2). Default changed to “4”.

47

Output Relay Configure

Default changed to “2” (motor running).

52

DB Enable

Default changed to 100%

61

Preset 0

Default changed to 6 hz

62

Preset 1

Default changed to 30 hz

63

Preset 2

Default changed to 60 hz

64-68

Preset 3-7

Default changed to 6 hz

70

Decel Time 2

Default changed to 3.0 sec

Advertising