AC Drive Firmware Up-Grade Procedure

necessary to remove the cradle of the Human Interface Module. On
the larger drives (B-H Frames), the Current Processor IC may be
located under the GMx Module, if the drive is so equipped.

4. Locate the Language Module for your specific drive.

5. Remove the module by squeezing the sides - in, and pulling the

module up & away from the MCB. Discard module.

6. Position the new Language Module on the Main Control Board,

using the silk screen outline on the board as a guide.

7. Carefully align the module connector with the Main Control Board

connector. Firmly press the module onto the board until fully seated.
The module will “snap” (lock) in place. This completes the
Language Module replacement.