PROBLEM

1. Empty product container

2. No power or incorrect voltage to
the dispenser

3. Signal cable unplugged

4. Hopper is full

5. Fuse and fuse holder

6. Main ON/OFF switch

7. Probe box LOW/OFF/HIGH
switches

8. Circuit board

9. Vacuum switches

10. Vacuum/Supply pump

1. Motor over heats

Replace or refill

(A1) Check the outlet for 120 volts
on two wire 120 volt dispenser.

(A2) Check the outlet for 200 volts or
240 volts ac for two wire 200 volt or
240 volt dispensers.

(B) Check circuit breakers or fuses.

Signal cable must be plugged in.

Product must not be touching probes
to fill.

Refer to

Service

- Fuse and Fuse

Holder for test procedures. See page
8

Refer to

Service

- Main ON/OFF

Switch for testing procedure. See
page 9

Refer to

Service

- Probe System. See

page 10

Refer to

Service

- Circuit Board for

testing procedures. See page 7

Refer to

Service

- Vacuum Switches

for testing procedures. See page 14

Refer to

Service

- Vacuum/ Supply

Pump for testing procedures. See
page 12

The thermal switch will reset, but
requires up to 30 minutes of cooling
time. See NOTE below.

TROUBLESHOOTING (cont.)

28791.1 011500

Product will not dispense

PROBABLE CAUSE

REMEDY

Motor thermal cutout (motor stops
running)

NOTE: This refill unit should not be used to initially fill the hopper. Running the motor for extended periods will

trip the thermal switch. The thermal switch will reset, but requires up to 30 minutes of cooling time.