1394 Ground Clamp Kit

Publication 1394-5.18 — May 2000

Installing Your 1394 Ground

Clamps

The 1394 ground clamp kit is designed for use with 1394C-SJTxx-x
(Series C) system modules and 1394C-AMxx (Series C) axis modules
only.

To install your system or axis module ground clamp:

1. Prepare one end of the cable for attachment to the cable shield

clamp by removing the outer insulation and braided shield from
the cable. Ensure approximately 51 mm (2.0 in.) of the insulated
cable wires are exposed (refer to Figure 1).

2. Remove another 22 mm (.875 in.) of insulation to expose the

braided shield underneath for clamp attachment.

Important: When cutting into the insulation use care not to cut

into the braided shield underneath.

3. Position the cable shield clamp over the exposed braided shield

(ensure clamp screw is behind clamp and not braided shield).

4. Tighten the clamp screw.

Important: Do not overtighten the clamp screw or damage to

the braided shield may result.

5. Thread the bracket screw into the bottom of the module and

tighten.

Figure 1
Series C Ground Clamp Installation

!

ATTENTION: To avoid a shock hazard, ensure that all
power to the system is removed before installing the
ground clamps.

1394 front view

System module

ground bar

Motor

feedback

cable clamps

Cable Preparation

Clamp Attachment

Wiring to System and Axis Module

Cable wires

Braided
shield
exposed

Cable
shield

clamp

Motor

feedback

or power

cable

Clamp

screw

Bracket

screw

Motor power
cable clamp

51 mm

(2.0 in.)

1

22 mm

(.875 in.)

1

Dimensions given are approximate and will vary
depending on the specific installation. Keep wires
as short as possible while maintaining adequate
stress relief.