Specifications spécifications, Technische daten specifiche especificaciones, I/o wiring data – Rockwell Automation 1492-IFMxxx Fusible Interface Modules User Manual

Page 4

Advertising
background image

Specifications

Spécifications

1492-IFM20F-F-2

1492-RIFM20F-F-2

1492-IFM20F-F24-2

1492-RIFM20F-F24-2

1492-IFM20F-F120-2

1492-RIFM20F-F120-2

1492-IFM40F-F-2

1492-IFM40F-F24-2

1492-RIFM40F-F24-2

1492-IFM40F-F120-2

2 Amps

12 Amps

0° C - 60° C

0 - 132V AC/DC

10 - 30V AC/DC

85 - 132V AC

Indicator Circuit Current

Courant circuit voyants

Strom, Anzeigeschaltkreis

Corrente circuito indicatori

Intensidad del circuito
de indicadores

Current/Circuit

Courant/Circuit

Strom/Schaltkreis

Corrente/circuito

Intensidad/circuito

Current/Module

Courant/Module

Strom/Modul

Corrente/modulo

Intensidad/módulo

Voltage Range

Tension

Spannung

Tensione

Voltaje

Catalog No.

Référence

Bestell-Nr.

N. Catalogo

Referencia

1492-IFM20F-F-2

1492-RIFM20F-F-2

1492-IFM20F-F24-2

1492-RIFM20F-F24-2

1492-IFM20F-F120-2

1492-RIFM20F-F120-2

1492-IFM40F-F-2

1492-IFM40F-F24-2

1492-RIFM40F-F24-2

1492-IFM40F-F120-2

Fuse Installation/Removal

Installation/retrait des fusibles

Ein- und Ausbau der Sicherung

Montaggio/smontaggio dei fusibili

Instalación/extracción de fusibles

1

2

2

3

4

5 x 20 mm
(max. 2.0A per output; 12A per module)
(2,0 A par sortie maximum; 12 A par module)
(max. 2,0 A je Ausgang, 12 A je Modul)
(max 2 A per uscita; 12 A per modulo)
(2,0 A máx. por salida; 12 A por módulo)

1

GOULD 34-015G
LITTELFUSE 097023
BUSSMAN FP-A3

Technische Daten

Specifiche

Especificaciones

0 - 132V AC/DC

10 - 30V AC/DC

85 - 132V AC

N/A

2.0mA

2.5mA

N/A

2.0mA

2.5mA

Reference Publications: Refer to 1770-4.1 and appropriate PLC I/O module installation manual.

4.33 in. (110 mm) W

3.27 in. (83 mm) H

2.74 in (70.5 mm) D

8.27 in. (210 mm) W

3.27 in. (83 mm) H

2.74 in (70.5 mm) D

.76 lb.

(344 g.)

1.1 lb.

(520 g.)

Dimensions

Dimensions

Abmessungen

Dimensioni

Dimensiones

Humidity

Humidité

Feuchtigkeit

Humedad

Umidità

Operating Temperature Range

Plage températures de fonctionnement

Betriebstemperaturbereich

Limiti temperatura di funzionamento

Rango de temperatura de funcionamient

5 - 95%

Maximum Recurring Peak Voltage

Tension de crele réurrente maximale

Maximale periodische Hochstspannung

Tensione massima di cresta ricorrente

Voltaje de cresta iterativo máximo

600 V

p

cULus (File: E10314, Guide No. NRAG)
Suitable for use in Class 1 Div 2 Groups A,
B, C and D Hazardous and Non-Hazardous
Locations.
Temperature Code = T3C at 60°C
CE: Compliant for all applicable directives
FM Class 1 Div 2 Groups A, B, C and D
Temperature Rating T3C = 60°C
(J.I. 3000590, all except relay modules)

For transients > 600 Vp use a UL recognized suppression device rated at 2.5 kV withstand.

Pour des transitoires > 600 Vp utilisez un dispositif de suppression certifié UL à 2,5 kV nominal de tenue.

Für Einschaltstöße > 600 Vp verwenden Sie einen UL anerkannten Entstörer, der bewertet wurde bei 2,5 kV standzuhalten.

Per transitori > 600 Vp usare dispositivo di soppressione riconosciuto da UL capace di sopportare 2,5 kV.

Para transitorios > 600 Vp use un dispositivo de supresión reconocido UL clasificado con 2,5 kV.

Power, input and output (I/O) wiring must be in accordance with Class I Division 2 wiring methods - Artticle 501-10(B)(1) of the National Ele

Add 0.39 in. to the width dimension for 1492-Rxx type modules.

Wiring information for your I/O module, AIFM module and cable (e.g. wiring diagram and pinouts)are available online at www.rockwellautomation.com/en/e-tools.
To obtain information follow this procedure.
1) In the Catalog Number BOX at the above online site type in the catalog number of the IFM, AIFM, etc. module you are using and click on Submit.
2) At the next screen displayed, click on the Modify key (lower left of screen).
3) Click on the areas that indicate NO SELECTION and enter your specific configuration information (e.g. I/O platform, I/O MODULE, ETC.).
NOTE: To obtain the wiring diagram, you must select th Pre-Wired Cable Connector selection.
4) Configure your 1492 cable by filing in the NO SELECTION areas.
5) Click on the ACCEPT key for the configured 1492 cable. At the next screen click on ACCEPT for the 1492 module.
6) The next screen (Configuration Results) displays the results of your specific configuration. The "supplementary Documents" column contains I/O wiring information
for the configuration (e.g. I/O Wiring Diagrams). configuration (e.g. I/O Wiring Diagrams).

Non-condensing

Sans condensation
Nicht kondensierend
Senza condensa
sin condensación

I/O Wiring Data

NOTICE

Approx. Shipping Weight

Poids d'embarquement approximatif

Ungefähres Versandgewicht

Peso approssimativo del carico

Peso aproximado al momento de
embarque

Catalog No.

Référence

Bestell-Nr.

N. Catalogo

Referencia

Standards

Normes

Standards

Standard

Estándares

WARNING

Explosion Hazard - substitution of components may impair suitability for Class I Division 2.
Explosion Hazard - Do Not Disconnect Equipment unless power has been switched off or the area is known to be Non-Hazardous.

SURGE SUPPRESSION follow the literature recommendations of the PLC module being used.
La section SUPPRESSION DES SURTENSIONS se trouve à la suite de la littérature qui contient les recommandations relatives au module PLC utilisé.
ÜBERSPANNUNGSSCHUTZ Bitte beachten Sie die Dokumentationsempfehlungen für das jeweils benutzte SPS-Modul.
Per la SOPPRESSIONE DEI PICCHI TEMPORANEI, seguire le istruzioni riportate nella documentazione in dotazione al Modulo PLC utilizzato.
SUPRESIÓN DE SOBRETENSIÓN, siga las recomendaciones indicadas en la documentación del módulo PLC respectivo.

PN-23116
DIR 40063-257 (Version 12)

Printed in U.S.A.

Advertising