Input Fuses

Internal input fuse: T10A (H.B.C.), not user accessible. The unit is tested and approved for
branch circuits up to 20A. An external protection is only required if the supplying branch has an
ampacity greater than this, however, in some countries local regulations might apply. Check also
local codes and requirements. If an external fuse is necessary or utilized, minimum requirements
need to be considered to avoid nuisance tripping of the circuit breaker. A minimum value of 10A
B- or 6A C-Characteristic breaker should be used. (1606-XLS480EE: 10A B- or C-Characteristic)

Sicherungen am Eingang

Das Gerät besitzt eine T10A (H.B.C.) Eingangssicherung, die nicht anwenderzugänglich ist. Das
Gerät ist geprüft und zugelassen zum Anschluss an Stromkreisen bis max. 20A. Ein zusätzlicher
externer Schutz ist nur erforderlich, wenn der Speisestromkreis mit einem höheren Wert
abgesichert ist oder nationale Richtlinien es vorschreiben. Falls ein externes Schutzelement
verwendet wird, soll dieses nicht kleiner als 10A B- oder 6A C-Charakteristik sein, um ein
fehlerhaftes Auslösen zu vermeiden. (1606-XLS480EE: 10A B- oder C-Charakteristik)

Indicators

Overload LED

DC-OK LED

DC-OK Contact

Normal mode

OFF

ON

Closed

During BonusPower

®

OFF

ON

Closed

Overload (Vout < 90%)

*)

OFF

Open

Output short circuit

*)

OFF

Open

Temperature Shut-down

*)

OFF

Open

No input power

OFF

OFF

Open

*) The overload LED is permanently on when the overload current is continuously flowing. During
the 17s rest period (hiccup), the red LED is flashing with a frequency of approx. 1.3Hz.

Anzeigelampen

Overload LED

DC-OK LED

DC-OK Contact

Normalberieb AUS

EIN

geschlossen

Während BonusPower

®

AUS

EIN

geschlossen

Überlast (Vout < 90%)

*)

AUS

offen

Ausgangskurzschluss *) AUS

offen

Temperaturabschaltung *)

AUS

offen

Keine Eingangsspannung

AUS

AUS

offen

*) Die „Overload LED“ leuchtet dauernd, wenn der Überlaststrom kontinuierlich fließt. Während
der 17s Auszeit im Hiccup Modus blinkt die LED mit einer Frequenz von ca. 1,3Hz.

DC-OK Relay Contact

(see Fig. 1)

This feature monitors the output voltage, which is produced by the power supply, and is
independent of a return voltage from a unit which is connected in parallel.
Contact closes when the output voltage reaches the adjusted value after turn-on of the power
supply or when the output voltage reaches 90% after a dip of the output.
Contact opens when the output voltage dips more than 10%. Short dips will be extended to a
length of 250ms. Dips shorter than 1ms will be ignored.
Contact ratings: max.: 60Vdc 0.3A, 30Vdc 1A, 30Vac 0.5A, Resistive load, min.: 1mA
Please note:
After turn-on of the power supply, the output voltage has to reach the adjusted level where the
DC-ok relay contact closes and the green DC-ok LED turns on. If this level cannot be achieved,
the red overload LED will stay on. This is an important condition to consider particularly, if the
load is a battery or the power supply is used for N+1 redundant systems.

DC-OK Relais Kontakt

(siehe Bild 1)

Diese Funktion überwacht die vom Gerät erzeugte Ausgangsspannung und lässt sich von einer
rückwärts eingespeisten Spannung nicht beeinflussen (z.B.: bei Parallelschaltung)
Kontakt schließt sobald nach dem Einschalten der Ausgang den eingestellten Wert erreicht
oder wenn nach einem Einbruch des Ausgangs die Spannung wieder > 90% des eingestellten
Wertes wird.
Kontakt öffnet sobald der Ausgang um mehr als 10% einbricht. Kurze Einbrüche werden auf
250ms verlängert. Einbrüche kürzer 1ms werden ignoriert.
Belastbarkeit: max.: 60Vdc 0.3A, 30Vdc 1A, 30Vac 0.5A, (R-Last), min.: 1mA
Zu beachten:
Nach dem Einschalten der Stromversorgung muss die eingestellte
Ausgangsspannung erreicht werden, damit der DC-ok Signalkontakt schließt und die DC-ok LED
angeht. Wird dieser Wert nicht erreicht, leuchtet die Overload LED. Dies kann bei
Batterieladeanwendungen oder bei N+1 redundanten Systemen von Bedeutung sein.

Output- and Overload Characteristic

The unit is designed to support loads with a higher short-term power requirement without
damage. The unit can deliver up to 720W output power for a defined period of time (Bonus time)
before it reduces the output power automatically to 480W. If the power requirement is
continuously higher than 480W and the voltage falls below approx. 85% of its nominal value (due
to the current regulating mode at overload), the unit shuts-off and makes periodical restart
attempts (hiccup mode). In such cases, the unit will be off for 17s followed by an on cycle of 4s
max. 720W. This cycle is repeated as long as the overload exists.
Output characteristic
(see Fig. 2)
The curve in figure 2 is valid for 24V units. The other output voltages have an equivalent and
proportional performance.
BonusPower

®

time (see Fig. 3)

Figure 3 shows the duration until the output voltage starts dipping when more than 480W is
drawn (controlled by software).

Ausgangs- und Überlastverhalten

Die Stromversorgung ist zur Versorgung von Lasten mit kurzzeitig hohem Bedarf an
Spitzenleistung. Die Stromversorgung kann für eine bestimmte Zeit (Bonuszeit) bis zu 720W
Ausgangsleistung liefern, bevor automatisch auf 480W zurückgeregelt wird. Wenn der
Leistungsbedarf kontinuierlich höher als 480W ist und durch die Stromregelkennline der
Stromversorgung die Ausgangsspannung unter ca. 85% fällt, schaltet die Stromversorgung ab
und macht periodische Startversuche (Hiccup-mode). In solchen Fällen schaltet die
Stromversorgung für 17s aus und macht dann einen neuen Startversuch, bei dem wieder für 4s
die 720W zur Verfügung stehen. Der Vorgang wiederholt sich solange die Überlast besteht.
Ausgangskennlinie (siehe Bild 2)
Die Kennlinie in Bild 2 gilt für 24V Geräte. Andere Ausgangsspannungen zeigen ein proportional
vergleichbares Verhalten.
BonusPower

®

Zeit (siehe Bild 3)

Das Bild 3 gibt die Dauer an bis die Ausgangsspannung sinkt, wenn mehr als 480W entnommen
werden. (softwaregesteuert).

Dielectric Strength

(see Fig. 4)

The output voltage is floating and separated from the input according to SELV (IEC/EN 60950-1)
and PELV (EN 60204-1, EN 50178; IEC 62103, IEC 60364-4-41) requirements. Type and factory
tests are conducted by the manufacturer. Field tests may be conducted in the field using the
appropriate test equipment which applies the voltage with a slow ramp (2s up and 2s down).
Connect all phase-terminals together as well as all output poles before the test is conducted.

A B C D

Type Test

(60s)

2500Vac

3000Vac

500Vac

500Vac

Factory Test

(5s)

2500Vac

2500Vac

500Vac

500Vac

Field Test

(5s)

2000Vac

2000Vac

500Vac

500Vac

Cut-off current setting

>15mA

>15mA

>40mA

>1mA

Isolationsfestigkeit

(siehe Bild 4)

Die Ausgangsspannung hat keinen Bezug zur Erde oder Schutzleiter und ist zum Eingang nach
den SELV (IEC/EN 60950-1) und PELV (EN 60204-1, EN 50178, IEC 62103, IEC 60364-4-41)
Standards getrennt. Typ- und Stückprüfungen werden beim Hersteller durchgeführt.
Wiederholungsprüfungen dürfen mittels geeigneten Prüfgenerators mit langsam (2s)
ansteigenden und abfallenden Spannungsrampen in der Anwendung erfolgen. Vor den Tests
sind alle Phasen wie auch alle Ausgangspole miteinander zu verbinden.

A

B

C

D

Typprüfung

(60s) 2500Vac 3000Vac 500Vac 500Vac

Stückprüfung

(5s) 2500Vac 2500Vac 500Vac 500Vac

Wiederholungsprüfung (5s) 2000Vac 2000Vac 500Vac 500Vac
Strom-

Abschaltschwelle

>15mA >15mA >40mA >1mA

Fig. 1 / Bild 1

DC-OK-Signal / DC-OK-Signal

Fig. 2 / Bild 2

Output Characteristic (typ.) / Ausgangskennlinie

Fig. 3 / Bild 3

BonusPower

®

Time / BonusPower

®

Zeit

Fig. 4 / Bild 4

Isolation / Isolation

250ms

90% V

ADJ

<1ms

10%

open

V

OUT

= V

ADJ

open

closed

closed

>1ms

Output Voltage

0

0

5

10

20

25

4

8

12

28V

16

20

24

40A

15

30

Output

Current

35

A

B

A

B

Short term <5s then auto

switching to curve +

Below 20Vdc hiccup mode

C

C

Continuously available

B

C

0
528W 576W 624W 672W 720W 768W

1

2

3

7

4

5

6

8

9

10s

Output Power

min

max

typ

A

D

C

B

B

Input

DC-ok

Earth

Output

-

+

N

L

Fig. 5 / Bild 5 Dimensions / Abmessungen

all units except 1606-XLS480EE

1606-XLS480EE

all units

Fig. 6 / Bild 6

Functional Diagram / Funktionsschaltbild

+

+

-

-

Output

Over-

Voltage

Protection

PFC

Converter

Output

Voltage

Regulator

Power

Converter

Output

Filter

DC-ok

Relay

Output

Voltage

Monitor

Output

Power

Manager

Temper-

ature

Shut-

down

Input Fuse
Input Filter
Input Rectifier
Active Inrush Limiter

V

OUT

L

N

DC-ok

Contact

Overload

LED

DC-ok

LED

*) except / außer 1606-XLS480EE

*)

10000044635 (version 01)

PU-362.012.38-10A

Advertising