Conversion: 1771-OMD to 1756-OA16

Conversion Module

1492-CM1771-LD006

Cable

1492-CONCAB005X

V. Wiring Diagrams (Cont’d)

There are several key application considerations and system specifications (bottom of drawing) when
using these components (conversion module, cable and input module). Read and understand these
considerations before installation.

WARNING

Conversion Module Installation and Application Considerations

(9)

10

L1-0+

OUT-0

1

OUT-1

2

OUT-2

3

OUT-3

4

OUT-4

5

OUT-5

6

OUT-6

7

OUT-7

8

OUT-8

11

OUT-9

12

OUT-10

13

OUT-11

14

OUT-12

15

OUT-13

16

OUT-14

17

OUT-15

18

Black

White

Red

Green

Orange

Blue

White/Black

Red/Black

Green/Black

Orange/Black

Blue/Black

Black/White

Red/White

Green/White

Blue/White

Black/Red

White/Red

Orange/Red

Blue/Red

Red/Green

L1-1+

20

9

L2-0

19

L2-1

A

1

00

19

01

3

02

4

03

5

04

6

05

7

06

8

07

9

E

10
11

10

12

11

13

12
13

15

14

16

15

17

16
17

18

20

14

2

Output 00

L1

L2

B

C
D

Output 01
Output 02
Output 03
Output 04

Output 05

Output 06
Output 07

Output 10

Output 11
Output 12
Output 13

Output 14

Output 15
Output 16

Output 17

L1

L2

+

-

24

21
22
23

25

LOAD

L1
L1

L1

This Bul. 1492 cable consists of a cable wired to one 1756-OA16 RTB. Recommended cable lengths of0.5M or 1.0M

(005=0.5M, 010=1.0M). See table 2 for other lengths.

The 1771-OMD module output current limits versus 1756-OA16 limits are as follows:

1771-OMD

1756-OA16 w/ 1492-CONCAB005X

a)

Current/Point

2A

0.5A

b)

Current/Module 8A

4A

c) Surge Current/Point

25A for 100ms

5A for 43ms

The 1771-OMD has a single 10A, 250V rectifier fuse (1/4 x 1 1/4 inch). The 1756-OA16 has a mechanical 3.15A @250V AC

slow blow fuse. Refer to the 1756-OA16 Installation Manual for details on electronic fusing.

The 1771-OMD is rated 184V to 250V AC. The 1756-OA16 is rated 74V to 265V AC. If the load source voltage is greater than

30V DC, then use the 1756-OC8 with the 1492-CM1771-LD008F conversion module.

Refer to your 1771-OMD and 1756-OA16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756

output module ratings are not exceeded.

[Reference Doc: 41171-007 (Version 00)]

PN-114278
DIR 10000060089 (Version 01)
Publication 1492-IN036B-EN-E

1756-OA16

1771-WH, WHF, WHFB Swing Arm
From 1771-OMD

Advertising