M670 Mounting and Wiring

To install the choke assembly, follow these steps:

1. Remove all power connected to the system.

2. Mount the M670 Choke Assembly on a metal surface near the

bottom of the drive cabinet using 1/4-20 hardware. Leave
sufficient clearance between the choke assembly and the drive
terminals to allow access to the terminals and provide proper
bend radius for the leads.

3. Terminate the motor leads at the U,V,W connections on the motor

as shown in the figure on the following page. An optional
terminal strip may be used between the choke assembly and the
motor if desired. A properly sized ground conductor from the
motor frame is also required. The ground conductor is routed
around (not through) the choke and connected to the Drive Power
Earth @ TB1-PE.

!

ATTENTION: Electric shock can cause injury or
death. Remove all power before working with this
product. Verify that the voltage on the bus capacitors
has discharged. The voltage must be zero.

From Drive TB1
M1/T1-U

To Motor
U (T1)

To Motor
V (T2)

To Motor
W (T3)

From Drive TB1
M2/T2-V

From Drive TB1
M3/T3-W