1336 PLUS, 1336 PLUS II & 1336 FORCE™ NEMA Type 1 Enclosure Kit

Installation

Access to the top, bottom and sides of the drive chassis is required to
assemble the kit. If the open chassis drive is already installed, remove
and lock-out all power to the drive, then label and disconnect all
wiring. External wiring will have to be rerouted through enclosure
knockouts once the kit has been installed.

Figure 1
Enclosure Kits – 1336S
/F-AA2 and -AA3

1. Mount the top, bottom and side plates to the chassis using the

supplied screws. Tighten all screws to 1.7 N-m (15 lb.-in.).

2. Install the front cover by sliding it up, then down to engage the

slots into the angled tabs. Swing the cover bottom “in” and secure
it with the captive screw. Tighten to 0.7 N-m (6 lb.-in.).

Figure 2
EMC Enclosure Kits – 1336S
/F-AE2 and -AE3

1. Mount the bottom plate to the chassis using the supplied screws.

2. Slide enclosure assembly over the chassis as shown.

3. Fasten the assembly to the chassis using the supplied screws.

Tighten all screws to 1.7 N-m (15 lb.-in.).

Figure 3
Enclosure Kits – 1336S
/F/T-AA4 and -AA5

1. Slide the side plates over the chassis tabs as shown.

2. Attach the top and bottom plates to the side plates by sliding the

tabs into the corresponding slots. Fasten the assembly to the
chassis using the supplied screws. Tighten all screws to 1.5 N-m
(13 lb.-in.).

3. Install the front cover by sliding it up, then down to engage the

slots into the angled tabs. Swing the cover bottom “in” and secure
it with the captive screw. Tighten to 0.7 N-m (6 lb.-in.).

Figure 4
EMC Enclosure Kits – 1336S
/F/T-AE4 and -AE5

1. Mount the bottom plate to the chassis using the supplied screws.

2. 1336

PLUS

II

drives using the AE4 Enclosure Kit require

replacement of a ribbon cable. Remove the ribbon cable between
the Main Control Board and Gate Drive Board (see Figure 4).
Replace this cable with the new supplied cable (with ferrite
block). Position the cable/block as needed to prevent obstruction
with the enclosure being installed.

3. Slide enclosure assembly over chassis as shown.

4. Fasten the assembly to the chassis using the supplied screws.

Tighten all screws to 1.5 N-m (13 lb.-in.).

Advertising