1397 – 5.16 August, 2013

1397 460-to-230V Conversion Kit

5

Setup

To reconfigure a drive for 230V AC operation, the following
parameters must be reset.

Important: Depending upon the application, additional parameter
adjustments may be required. If additional options are installed,
different parameter settings may be required. Perform the Start-Up
and Adjustment procedure in the 1397 User Manual to verify all
parameter settings.

Motor Armature Amps

P.045 [Motor Arm Amps]

Reset to match the motor’s nameplate armature Amps.

Motor Armature Volts

P.046 [Motor Arm Volts]

Reset to match the motor’s nameplate armature voltage.

Nominal AC Input Voltage

P.051 [Motor AC Volts]

Reset to match the nominal AC line RMS voltage.