1397 – 5.16 August, 2013
1397 460-to-230V Conversion Kit
5
Setup
To reconfigure a drive for 230V AC operation, the following
parameters must be reset.
Important: Depending upon the application, additional parameter
adjustments may be required. If additional options are installed,
different parameter settings may be required. Perform the Start-Up
and Adjustment procedure in the 1397 User Manual to verify all
parameter settings.
Motor Armature Amps
P.045 [Motor Arm Amps]
Reset to match the motor’s nameplate armature Amps.
Motor Armature Volts
P.046 [Motor Arm Volts]
Reset to match the motor’s nameplate armature voltage.
Nominal AC Input Voltage
P.051 [Motor AC Volts]
Reset to match the nominal AC line RMS voltage.