Rockwell Automation 1585BP UTP Plug User Manual

Installation instructions bulletin 1585bp utp plug

Advertising
background image

1

Installation Instructions

Bulletin 1585BP UTP Plug

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

Refer to the product catalog pages for additional information.

Cut the rip cord as
close to the jacket as

possible. Fan pairs into
proper color code (see next
frame).

Using a cable stripper,
remove approximately

38 mm (1.5 in.) of sheath-
ing.

3

4

Place modular plug
over wire ends being

sure to maintain color code.
Insure that the pairs are in-
serted all the way into the
modular plug including the
inner jacket. The inner jack-
et should be directly under
the plug’s strain relief tab.

7

8

Using a crimp tool
(1585A--JCRIMP),
terminate the modular
plug to the cable.

Product includes: flex
nut, plug assembly,

and modular plug.

1

Place plug housing
over the industrial

cable as shown, flex nut
may need to be loosened.

2

Note: Outer cable
diameter range 4

…8 mm

(0.160

…0.315 in.)

5

6

T568A

Color Code

T568B

Color Code

Color Key:

1=White/Green

2=Green

3=White/Orange

4=Blue

5=White/Blue

6=Orange

7=White/Brown

8=Brown

Color Key:

1=White/Orange

2=Orange

3=White/Green

4=Blue

5=White/Blue

6=Green

7=White/Brown

8=Brown

= Tip

= Ring

1

8

2 3 4 5 6 7

Pair 3

Pair 1 Pair 4

Pair 2

1

8

2 3 4 5 6 7

Pair 1 Pair 4

Pair 2

Pair 3

After fanning pairs to
proper color code,

hold the pairs close to the
jacket and trim conductors
leaving 12 mm (0.5 in.) ex-
tending from the inner jack-
et.

12 mm

(0.5 in.)

Insert the modular
plug into the plug

housing. Align the latch with
the LATCH slot, depress
latch and insert plug into
plug housing until it bottoms
out.

Slide the plug housing
up the cable and align

with the modular plug.

9

10

Advertising