Fault Codes

Setting the Operating Speed Before
Starting the Unit

Standard units: Use the speed potentiometer or
other user-supplied external speed reference
device.

Units with local operator controls: As shipped
from the factory, the unit receives its speed

reference from the keypad. Use the

key to

increase the speed reference and the

key

to decrease the speed reference.

To use the analog input terminals for the speed
reference, setup switch 2 (Speed Reference
Select) must be in the ON position. In this case,

the

keys are not used.

At subsequent power ups, the unit will use the
last speed reference setting selected before
power was removed.

Using the Local Operator Controls

1329I
Integrated Drive/Motor
(Series B)

Quick Reference

Fault Code

Fault Description

Communication Loss

Keyboard Disconnected

Parameter Checksum

Keypad connected while under power

DeviceNet Communication Fault
(

X

= E, F, L, P, or U)

Keypad connected while under power

Keypad Redundant Start

Function Loss

Overvoltage

EEPROM Drive ID

Undervoltage

Overcurrent

Overtemperature

Overload

TB Redundant Start

Internal Fault

(

NNN

= a number between 0 and 999)

X

Desired Action

User Steps

Start the unit.

Press the green

key.

Stop the unit.

Press the red

key.

Change motor
rotation direction.

Press the

key.

Clear faults or abort
Auto Restart
sequence.

Press the

key.

Decrease the speed
reference.

Press the

key until the

speed reference displayed
is the desired value. The

longer the

key is held

down, the faster the value
will change.

Display the current
speed or load.

Press the

or

key once.

The display will return to indicating
speed in RPM or %load after three to
five seconds.

Display the speed in
RPM.

No action required; speed in RPM is
the default display based on terminal
12.

Display %load.

Close switch on terminal 12.

Increase the speed
reference.

Press the

key until the

speed reference displayed is the

desired value. The longer the

key is held down, the faster the value
will change.

RESET

IMPORTANT:

This publication is designed as a reference

tool. The Bulletin 1329I

User Manual

and 1329I

DeviceNet

Option User Manual

must be consulted for more detailed

information about operation and hazards of personal
injury.