Recommended lubricant, Lubrication procedure, Lubrication instructions – Rockwell Automation 1329R Std. Industrial AC Induction Motors User Manual

Page 16

Advertising
background image

16

Standard Industrial AC Induction Motors

Recommended Lubricant

For motors operating in ambient temperatures shown below, use the
following lubricants or their equivalent:

Ball Bearing Motors

Roller Bearing Motors

Lubrication Procedure

Anti-friction bearings may be lubricated with the motor running or
stationary. However, stationary with the motor warm is preferred.

1. Locate the grease inlet, clean the area and replace the pipe plug

with a grease fitting (if the motor is not equipped with grease
fittings).

2. If motor is equipped with grease drain plug, remove plug and

loosen any hardened grease that may block drain.

3. Add the recommended volume of the lubricant using a hand

operated grease gun.

4. Run the motor for two hours.

5. Replace the pipe plug in grease drain plug.

6. Grease may not relieve from drain. Use only volume shown in

Table E

.

Lubrication Instructions

1. Select Service Condition from

Table C

.

2. Select Lubrication Frequency from

Table D

.

3. Select Lubrication Volume from

Table E

.

4. Lubricate the motor at the required frequency with the required

lubricant volume in accordance with Lubrication Procedure
above.

Operating Temperature:

–25 to 50 degrees C (–15 to 120 degrees F)

Chevron Oil – SRI No. 2
Exxon – Unirex N2
Shell Oil Co. – Dolium R
Texaco, Inc. – Premium RB

Minimum Starting Temperature

–60 degrees C (–76 degrees F)

Shell Oil Co. – Aeroshell 7

Operating Temperature:

–25 to 50 degrees C (–15 to 120 degrees F)

Chevron Oil – Black Pearl EP No. 2
Texaco, Inc. – Premium RB