Rockwell Automation 1102C-CP46x 400A / 600A Vacuum Contactor Control-Pak User Manual

Page 2

Advertising
background image

42052-089

G. Ushakow

N/A

N/A

N/A

42052

1006490

1

INSTRUCTION SHEET

BULLETIN 1102C 400A/600A VACUUM CONTACTOR

CONTROL-PAK

2-20-04

Mark Jutz

2-20-04

D. Josef

2-20-04

2

2

REVISION

AUTHORIZATION

DIMENSIONS APPLY BEFORE

SURFACE TREATMENT

H

A

B

C

D

E

F

G

(DIMENSIONS IN INCHES)

TOLERANCES UNLESS

OTHERWISE SPECIFIED

REFERENCE

SHEET

OF

DWG.

B

DR.

CHKD.

APPD.

DATE

DATE

DATE

±

±

±

ANGLES:

.XXX:

.XX:

THIS DRAWING IS THE PROPERTY OF

THE ALLEN-BRADLEY CO. INC.

AND MAY NOT BE COPIED, USED OR

DISCLOSED FOR ANY PURPOSE EXCEPT

AS AUTHORIZED IN WRITING BY

THE ALLEN-BRADLEY CO. INC.

LOCATION : MILWAUKEE,

WISCONSIN

U.S.A.

SIZE

1

2

3

4

5

6

7

8

E - DOC

Control-Pak Replacement (Cont'd)

42052-089-01 (1)

Printed in U.S.A.

PART

NO.

MATERIAL

CHG.

CHAR.

SIZE

FLAT

FOLD

-01

1

TWO SIDES PRINTED

8-1/2" W x 11" H

BODY STOCK WHITE

BODY INK BLACK

4-1/4" W x 5-1/2" H

6. Install the new Control-Pak (Figures 3A & 3B). First, rotate the Retainer upwards. Next, insert the lower tab into
the recess on the side of the contactor base. With proper installation, the Actuator will fit into the hole in the slot in the
side of the contactor housing. Using a thin rod or flat blade, push the Actuator up or down as necessary to insert it into
the slot mentioned. Rotate the Retainer to its original position, which will slide over the upper tab on the Control-Pak.

7. Confirm position of (2) retainers (adjust if necessary) (See Figure 1).

8. Reinstall the cover and secure it with the original mounting hardware. NOTE: Cover must fit under metal bracket
on Control-Pak.
Tighten the four screws in a diagonal pattern to 5 lb-inches. (Figure 1).

9. Reattach the coil wire leads and any auxiliary control wires to the Control-Pak (tighten to 7 lb-inches).

10. Reinstall the contactor.

11. Reconnect the line and load conductors and tighten the main terminal hardware and bolts to 180 - 210 lb-inches.

Actuator
must fit into
slot shown

Figure 3A

Figure 3B

Control-Pak
Actuator

Thin rod or flat blade