Wiring Procedure

1. Cutting the Cable

S Cut cables perpendicular to the length of the cable
S To prevent short-circuits, cut the cable with a sharp

instrument and be sure there are no whiskers on the
conductors.

2. Connecting the Cable

S Align the cable labels and cable colors, and place the

cable on the connector.

S The cover is translucent. Visually confirm that the cable

has been inserted all the way to the back.

3. Assembling the Connector

S Before assembling connectors, check that the cable is

inserted all way to the cable stopper and be sure that it
is securely connected.

S Grip the connector in the center with the crimp tool and

assemble the connector. When finished, confirm that the
connector has been properly assembled.

S Confirm that the locks on the housing are completely

caught on the hooks on the cover.

Pressure-welding

Pressure-weld the

connector until

there is no gap.

Pressure-welding

Before pressure-welding

After pressure-welding

Cover hook

Basic Specifications

Rated current

5 A

Rated voltage

25V DC