6 ArmorPoint I/O Field Potential Distributor, Series A

Install the ArmorPoint Field
Potential Distributor (FPD)

To install the FPD, proceed as follows.

1. Using a bladed screwdriver, rotate the keyswitch on the

mounting base clockwise until the number 8 aligns with the
notch in the base.

2. Position the FPD vertically above the mounting base. The FPD

will bridge two bases.

3. Push the FPD down until it engages the orange latching

mechanism. You will hear a clicking sound when the FPD is
properly engaged.

The locking mechanism will lock the FPD to the base.

Remove the ArmorPoint Field Potential Distributor From the
Mounting Base

To remove the FPD from the mounting base:

1. Put a flat blade screwdriver into the slot of the orange latching

mechanism.

2. Push the screwdriver toward the I/O module to disengage the

latch.

The module will lift up off the base.

3. Pull the module off of the base.

Module will bridge two bases.

31416-M

Advertising