Removing and Replacing the Line Interface Module Internal Components 3

Catalog Number
Explanation

Line Interface Module (LIM) catalog numbers and descriptions are
listed in the table below.

Cat. No.

Input
Voltage

Current
Rating

Description

2094-AL15S

230V

15 A

230V ac auxiliary power output.

Customer-configurable
branch-circuit protection. This
feature provides the option for
connecting CB2 and CB3 before or
after the main (CB1) disconnect.

Refer to the Line Interface Module
Installation Instructions, publication

2094-IN005

, for more information.

24V dc power output with 20 A current capacity.

Branch circuit protection and disconnect when used
with the Variable Depth Rotary Mechanism (catalog
number 140U-H-RM12B).

Power to multiple Bulletin 2093 or 2094 power rails.

Internal 24V dc I/O line filter.

Internal 230V ac control line filter.

External (customer supplied) three-phase line filter.

2094-AL25S

25 A

2094-AL50S

50 A

2094-AL75S

75 A

2094-BL10S

460V

10 A

2094-BL25S

25 A

2094-BL50S

50 A

2094-BL75S

75 A

2094-XL75S-C1

230/460V

75 A

110V ac auxiliary power input.

2094-XL75S-C2

230/460V

75 A

230V ac auxiliary power input.

2094-AL09

230V

20 A

24V dc power output with 8 A current capacity.

Internal three-phase line filter.

Internal 230V ac control line filter.

2094-BL02

460V

30 A