North American Hazardous Location Approval

The following information applies when operating this
equipment in hazardous locations.

Informations sur l’utilisation de cet équipement en
environnements dangereux.

Products marked "CL I, DIV 2, GP A, B, C, D" are suitable for use in Class
I Division 2 Groups A, B, C, D, Hazardous Locations and nonhazardous
locations only. Each product is supplied with markings on the rating
nameplate indicating the hazardous location temperature code.
When combining products within a system, the most adverse
temperature code (lowest "T" number) may be used to help
determine the overall temperature code of the system. Combinations
of equipment in your system are subject to investigation by the local
Authority Having Jurisdiction at the time of installation.

Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne conviennent qu'à
une utilisation en environnements de Classe I Division 2 Groupes A, B,
C, D dangereux et non dangereux. Chaque produit est livré avec des
marquages sur sa plaque d'identification qui indiquent le code de
température pour les environnements dangereux. Lorsque plusieurs
produits sont combinés dans un système, le code de température le
plus défavorable (code de température le plus faible) peut être utilisé
pour déterminer le code de température global du système. Les
combinaisons d'équipements dans le système sont sujettes à
inspection par les autorités locales qualifiées au moment de
l'installation.

WARNING: EXPLOSION HAZARD

Do not disconnect equipment unless power

has been removed or the area is known to be
nonhazardous.

Do not disconnect connections to this

equipment unless power has been removed
or the area is known to be nonhazardous.
Secure any external connections that mate
to this equipment by using screws, sliding
latches, threaded connectors, or other
means provided with this product.

Substitution of components may impair

suitability for Class I, Division 2.

If this product contains batteries, they must

only be changed in an area known to be
nonhazardous.

AVERTISSEMENT: RISQUE D’EXPLOSION

Couper le courant ou s'assurer que

l'environnement est classé non dangereux
avant de débrancher l'équipement.

Couper le courant ou s'assurer que

l'environnement est classé non dangereux
avant de débrancher les connecteurs. Fixer
tous les connecteurs externes reliés à cet
équipement à l'aide de vis, loquets
coulissants, connecteurs filetés ou autres
moyens fournis avec ce produit.

La substitution de composants peut rendre

cet équipement inadapté à une utilisation
en environnement de Classe I, Division 2.

S'assurer que l'environnement est classé

non dangereux avant de changer les piles.