Rockwell Automation FlexPak Plus, MinPak Plus DC Drive Torque Taper Kit for NRG 14C224 User Manual

Page 3

Advertising
background image

Torque Taper Kit for Non-Regenerative FlexPak Plus and MinPak Plus DC Drives

3

If the strip does not break immediately, start the process and allow the winder to begin winding.
Accelerate to the normal running speed. On the Torque Taper module, adjust the CORE TORQUE
potentiometer to obtain the desired strip tension at the beginning of the coil (CCW decreases
tension).

Step 12. As the coil or package increases in diameter, adjust the TORQUE TAP. ADJ. potentiometer to

maintain the proper tension (CCW increases tension). Adjust in small increments as the diameter
grows.

Important: Depending on the amount of torque taper desired and the size of the coil or package being wound,

the drive may go into current limit. However, the Current Limit potentiometer on the Regulator
module must never be set higher than 100% of the nameplate current rating on the motor.

Step 13. Stop the drive. Disconnect, lock out, and tag input power to the drive.

Step 14. Reattach the cover to the drive.

Step 15. Remove the lock out and tag.

This completes the installation of the Torque Taper kit.

Figure 2 – Regulator Module Jumper Locations

Remove J7 and J8 if you are
using the Torque Taper kit.

Advertising