60.2 Format Alarm

When set to Normal (default), an alarm will be triggered whenever the format of the
selected input video signal is incompatible with the selected output format (refer to
the matrix of inputs and compatibilities presented in Chapter 2). If you want the
FS1 alarm to only trigger on hardware failures, you can suppress the Format Alarm.

60.3 Reference Alarm

This parameter controls how the FS1 responds to various reference video signal
conditions. When set to Normal, the alarm will trigger when:

1. The reference signal is incompatible with the selected output format or is not

detected at all.

2. The reference signal is required, due either to 1.1 Output format set to “Follow

Ref” or 6.1 Genlock Source set to “Reference.”

If you want the FS1 alarm to only trigger on hardware failures, you can suppress the
Format Alarm.

60.2 Format Alarm

Description of Choices

Parameter Adjustments:

Normal

(default)

Suppress

Alarm triggers if the format of the selected input video signal is incompatible with

the selected output format.

Alarm will not be triggered by a format incompatibility.

60.3 Reference Alarm

Description of Choices

Parameter Adjustments:

Normal

(default)

Suppress

The alarm triggers if the reference is missing or incompatible with the selected

output format.

Alarms are not triggered if the reference is missing or incompatible with the output.