Voltikus rear panel explained, Replacing a voltikus fuse – Antelope Audio Zodiac Platinum DSD DAC User Manual

Page 17

Advertising
background image

1

15

14. Voltikus Rear Panel Explained

31. Fuse compartment

Takes two fuses: 0.8A, 250 VAC, 5 mm x 20 mm, Type F.

32. Power switch

Toggles power on/off.

33. IEC AC Input C14 Male Connector

For use with supplied AC Power cable.

34. Ground/Lift switch

Toggles grounded or lifted state.

35. 18 VDC Output

For use with supplied Antelope DC Power cable only.

15. Replacing a Voltikus fuse

If the power light is not illuminated and the Voltikus is plugged into a working AC power outlet with

the power switch in the on position, the fuse may need to be replaced.

● Disconnect the power cord from the electrical outlet.

● Insert a flat blade screwdriver into the notch at the bottom edge of the fuse holder (31) to

release it. (See image below).

● Remove the fuses from the fuse holder. Replace them with 0.5A 250V Time Lag (Slo-Blo)

Littelfuse Inc. P/N: 0218.500MXP

31

32

33

34

35

Advertising