Balboa Water Group EL2000 Configuration Guide User Manual

Instruments balboa, Balboa, Incorporated

Advertising
background image

Output Features

Quadrant

J1

+ W1

– 2-Speed Pump 1

4-A

J2

+ W7

– Circ Pump or Fiber Optic (Separate Relay 120V or 240V) 6-C

J3

+ W2

– 1-Speed Blower (with 1-speed Pump 2) W15 to J97

7-C

– OR 1-Speed Pump 3 (with 1-speed Pump 2) W15 to J97

J4

+ W8

– Audio Visual (always hot - no relay)

2-A

J5

+ W12

– 2-Speed Pump 2 (with NO Blower on J3) W15 to J98

7-C

– OR 1-Speed Pump 2 (See J3/W2)

J9

+ W13

– Ozone (Separate Relay 120V or 240V)

6-C

J12 + W9

– Spa Light (12V or 120V) Check J37 Setting

5-B

EL2000 Mach 3 Configuration Guide

EL2000 Mach 3 Expander Board Options

Instruments

Balboa

Incorporated

G

R

B

W

J6

J3

J2

W12

K1

F10A 250V

F5

X-B
Used for a 1-speed Blower output ONLY.
• W15 (9-A) connected to J98 (8-B)

X-P
Used for a 1-speed Pump or Mister output.
• W15 (9-A) connected to J97 (9-B)

X-P632
Used for a 2-speed Pump output or for two 1-speed
Pumps. Can also be used for other optional setups.
• J6 on X-P632 connects directly to Black AC (1-C) on
the main EL2000 PCBA.

PN 53680

PN 53681

X-P231
Can replace the X-P in cases where branch circuit
protection is needed for high amperage devices that
would over-burden power input fuse F7 (1-B) on the
main PCBA. This allows J6 on the X-P231 to connect
directly to Black AC (1-C) on the main EL2000 PCBA.

X-O3

PN 53426

X-FOW Kit
Special setup with X-03 and Adapter PN 25338 to operate a fiber-optic light and
color wheel independently. Required to operate a Fiber Optic when a Circ Pump
is installed on Main PCBA at J2.

Document PN 40483_L

04-05-2007

PN 53912

G

R

B

W

G

R

B

W

J6

J7

J4

J5

J2

W12

K1

G

R

B

W

J6

J4

J2

W12

K1

Adapter PN 25338

To J5 on X-O3

To Spa Light on
EL2000
(120V Setup)

PN 53310

PN 53544

X-TB
Used for a multi-speed Blower (requires v29+ software and “bL” set to “2” or “3”)
Or can be used for a 1-speed Blower.
• W1 connects to Red or White AC on Main PCBA.
• J3 connects to Black AC on Main PCBA.
• J2 connects to J6 (Ext. Rly) on Main PCBA.

PN TBD

ADCM SPLITTER KIT
Required when using a Menu-driven panel.
Kit includes PCB, stand-offs, and cable.
Note: Software v29 or higher required.
• J2 connects to ADCM IN (J69) on main PCBA.
• J3 connects to Menu Panel or Transceiver.
• J6 connects to tester or F.A.S.T. station.

PN 54530

X-Mount P
Used for mounting any Expander Board
in a plastic enclosure.
Standoffs attach to heater mounting bracket.

PN 53933

A

B

C

D

E

F

A

B

C

D

E

F

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

RED AC

WHT AC

J53

J23

J19

J43

J48

K12

U4

J50

J52

BLK AC

J66

J65

J63

J64

J42

J54

J56

J55

J25

J57

J26

TB1

CLASS G

FUSE 30A

CLASS G

FUSE 30A

F6

F7

F4

K4

W1

F2

K7

T1

HTR2

HTR1

FUSE
0.3A 250V

K6

K8

G

R

B

W

J79

J46

J45

J81

12VAC

ADCM

J37

J4

J7

J74

W8

1

2

3

FUSE
3A 250V

TORQUE
RANGE
FOR TB1:
27-30 IN. LBS.

HOT

BLACK

NEUTRAL

WHITE

HOT

RED

Balboa

J11

J8

BARCODE

G

R

B

W

W

W

J12

J14

W13

W12

K13

W20

W15

BALBOA INSTRUMENTS, INC. MADE IN U.S.A.

EL2000 TC MACH III COPYRIGHT 2005
P/N 22896 REV B

K10

J2

MAIN
PANEL

MAIN
PANEL

MAIN
PANEL

AUX
PANEL

AUX
PANEL

J9

J5

J6

K3

J3

K2

W2

F5

W9

W7

REMOTE

K11

K9

J1

K1

G

R

B

W

G

R

B

W

G

R

B

W

J86

J80

J60

J69

J20

J10

FUSE 10A 250V

J39

J71

J70

J98

J89

J91

J17

J15

J13

J83

J22

J24

J82

J36

TST

SENS. A

SENS. B VAC

EXT. 2SP PUMP 3

EXT. RLY

AUX. F

J72

CFG

SWITCHBANK A

SWITCHBANK B

J90

J97

G

R

B

W

J85

G

R

B

W

J1

W1

J7

J6

F30A 480V

X-P231
PN 53681

P/N 22909 REV B

G

R

B

W

J1

W1

J2

J6

F30A 480V

X-P632
PN 53680

P/N 22909 REV B

J6

J3

J2

J1

TEST

Balboa

MADE IN U.S.A.
P/N 22039_ A

© 2006

ADCM SPLITTER
PN 54530

G

R

B

W

J1

J3

J5

J2

W1

RED/WHT

BLK/12VAC-A

PN 22051_X1

2006

BLOWER

F1

Pb

Balboa

C

Advertising