Balboa Water Group EL8000 Configuration Guide User Manual

Instruments balboa, El8000 expansion options, Incorporated

Advertising
background image

Output Features

Quadrant

J1 + W1

– 2-Speed Pump 1

3-B

J2 + W6 – Output tied to Pump 1 Low (J39 - P1-Lo)

4-B

– OR output tied to Circ Pump (J39 - Circ)

J3 + W7 – Circ Pump

5-B

J4 + W13 – Ozone (Separate Relay 120V or 240V)

7-B

J5 + W8

A.V.

6-B

J6 + W12 – 3-speed blower

8-B

J10 + W9

Spa Light (12V or 120V/240V) (Check J37 setting) 8-C

J7 + W2 – Misc (120V or 240V) (Check J47 setting)

2-C

J8 + W5 – Fiber Optic (12V or 120V/240V)

4-C

(Check J47 + J49 setting)

J9 + W4 – Option (on/off, no timeout) or

5-C

Mister (12V or 120V/240V) (Check J29 setting)

J11 + W14 – 2-Speed Pump 2

5-D

J12 + W10 – 2-Speed Pump 3 (W30 to J94)

7-D

W3

– Sets Transformer Voltage (120V or 240V)

4-E

(Setting must match transformer installed in system.)

EL8000 Mach 3 Configuration Guide

EL8000 Expansion Options

Instruments

Balboa

Incorporated

X-P632
Used for an additional 2-speed Pump output.
Relay control J2 plugs into the EXP I/O connector J36 on
the Main PCBA (Quadrant 7-E, near W10).

Expander boards that REPLACE the Blower function:
Relay control for these options is connected to J21 on the
Main PCBA (Quadrant 9-C, near W9). Do not use the
Blower Connector J6 if one of these is used.

X-P

PN 53544

Used for an on-off Device without a fuse.

X-B

PN 53310

Used for an on-off Device with 10A fuse.

X-P231

PN 53681

Used for an on-off Device with 30A fuse.

PN 53680

Document PN 40593_F

04-05-2007

PN 53914

X-Mount M
Used for mounting any Expander Board
in a metal enclosure.
Bracket attaches to heater mounting straps

Pump 5

P

ump 2

To

J

1

1

PS-25
Used to split the output from the Pump 2 Connector (J11)
into a single-speed Pump 2 and single-speed Pump 5.
White wire quick connect goes to Main PCB Red AC for
240 Pumps or to Wht AC for 120V Pumps.

PN 25094

White

Red

White

Green
Black

Green

White

Red

White

Green
Black

Green

Pump 4

P

ump 3

T

o

J12

PS-34
Used to split the output from the Pump 3 Connector (J12)
into a single-speed Pump 3 and single-speed Pump 4.
White wire quick connect goes to Main PCB Red AC for
240 Pumps or to Wht AC for 120V Pumps.

PN 25093

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

WHT AC (120V)

BLK AC

RED AC (240V)

J66

J65 J68

J64

J63 J67

J58

J57 J62

J54

J59

J60 J56

J61

J74

J75 J53

J95

J46

J55

J44

J52

J28

J27

J35 J43 J23 J32

TB1

FUSE 30A CLASS G

FUSE 30A CLASS G

F6

F7

K7

HTR2

HTR1

K6

K8

FUSE 1/2A 250V

F2

K4

K3

K2

J37

K16

J7

J8

K11

K9

K10

G

R

B

W

G

R

B

W

G

R

B

W

J9

J11

G

R

B

W

J1

G

R

B

W

G

R

B

W

J12

G

R

B

W

G

R

B

W

G

R

B

W

G

R

B

W

J2

J3

J4

J5

J6

J49

J47

BLK-A

BLK-A

P1-LO

CIRC

J39

K5

K13

K1

K14

W5

W4

W30

W14

W10

W6

W7

W8

W12

W9

W13

W15

W2

W1

W3

BARCODE

SWITCHBANK A

SWITCHBANK B

J17

J84

J15

J83

J22

K12

K15

J86

J92

J85

F1

J24

J82

TST

AUX. F

CFG

SEN. A

SEN. B

VAC

J91

J21

TV 1

J51

TV 2

J36

TRC6

J19

J18

UV

F5

FUSE 10A 250V

J90

J94

J76

J14

J93

J79

FUSE 3A 250V

F4

W

W

J10

U4

REMOTE

EXP I/O

ADCM

J69

J20

J25

J38

J81

J45

J41

J33

1

1

2

2

3

3

J29

1

1

2

2

3

3

12VAC-B

12V

AC-B

BLK-A

12VAC-B

1

2

3

J89

J26

J48

J50

J42

J77

MAIN P

ANELS

AUX P

ANELS

12 V

A

C

J16

J40

J34

J31

J73

J72

J71

J70

TORQUE
RANGE
FOR TB1:
27-30 IN. LBS.

HOT

BLACK

NEUTRAL

WHITE

HOT

RED

BALBOA INSTRUMENTS

, INC.

EL8000 Mach 3

COPYRIGHT 2005

P/N 22041 REV

A

MADE IN U

.S

.A.

G

R

B

W

J96

J101

J100

J13

J97

J30

Red

Black

White

Green

Sequencer

SS Pump

SS Pump

ELS-VALVE
Used to split the output from a single-speed Pump to allow
a Valve Sequencer to be powered by the pump’s output.

PN 22934

G

R

B

W

J1

W1

J2

J6

T30A 480V

X-P632
PN 53680

P/N 22909 REV B

ADCM SPLITTER KIT
Required when using a Menu-driven panel.
Kit includes PCB, stand-offs, and cable.
Note: Software v29 or higher required.
• J2 connects to ADCM IN (J69) on main PCBA.
• J3 connects to Menu Panel or Transceiver.
• J6 connects to tester or F.A.S.T. station.

PN 54530

J6

J3

J2

J1

TEST

Balboa

MADE IN U.S.A.
P/N 22039_ A

© 2006

ADCM SPLITTER
PN 54530

Advertising