Gaskets – Bally Refrigerated Boxes Walk-In Service Manual User Manual

Page 3

Advertising
background image

REV: 5/2013

IM-268S-11 2013 © Bally Refrigerated Boxes, Inc.

3

GASKETS

Replacing magnetic door gasket on Hinged Walk-In doors


A. Remove the old gasket and clean the surface

where the new gasket will be placed.

B. Position the new gasket, starting at the top

corners. Tap it into place with a wood block and

hammer. Do not stretch the gasket to make it fit.
Be sure the gasket lies flat. See Figure 2.

C. Check door for proper operation and seal.

Part Numbers:

#016543 – 24” x 78”
#017402 – 30” x 78”
#017403 – 30” x 84”

#016546 – 34” x 78”
#016547 34” x 84”
#054117 – 36” x 78”

#054119 – 36” x 84”
#032999 – 42” x 78”

#032999 – 42” x 84”
#016548 – 48” x 84”

#016549 – 60” x 84”

A. Open the door 90 degrees.
B. Grasp the old gasket and pull it away from the

interior skin of the door. Clean the surface where
the new gasket is to be placed.

C. Position the new gasket; tap it into place with a

wood block and hammer. Do not force the

gasket into place; excessive force may damage

the door cap.

D. If the gasket binds when the door is closed, the

gasket is too wide. Be sure the gasket is properly

centered, and trim the ends as needed. See
Figure. 3.

Part Numbers:

#016614 – 30” Door
#016611 – 34” Door

#054028 – 36” Door

#016612 – 42” & 48” Doors

#016613 – 60” Door

Figure 2

Figure 3

Advertising