Bally Refrigerated Boxes Duro-Last Membrane Roof User Manual

Page 5

Advertising
background image

REV: 10/2014

IM-338-91 2014 © Bally Refrigerated Boxes, Inc. 5

Installation instructions for Bally buildings abutting

existing buildings

Note: Spend a few minutes reviewing this material before

you begin installing the membrane roof. Using Figure 8,

find the condition that applies to your installation.
Condition A applies when a long side of the Bally

structure abuts an existing building; Condition B when a

short side abuts, and Condition C when both a short
and a long side abut.

Condition A: Long side of Bally structure’s membrane

roof abuts existing building.
Note: If Condition A exists, follow steps 1, 2 and 3 below

before referring to material on pages 4 and 5.

1. The width of your roofing material will be 6" wider

than the width shown in the chart on page two.

2. Fold the membrane material back before rolling up

roof material. See Figure 9. Note: Tabs will run
perpendicular to building wall. (See Figure 9) Space

between building wall and existing building must be
flashed first. Perforated material is recommended to
allow circulation if Bally building is a cooler or freezer.

(See Figure 10) .

3. Included with the membrane roof will be two outside

corner pieces. (See Figure 11) Install these corners
before installing your membrane roof. Caulk first. (See

Figures 11 and 12)

4. On page 2, find correct chalk line dimension.

Complete installation of roofing material on ceiling
panels, following instructions on pages 4 and 5.

5. Flash roof material to building wall following Figure

13.

6. At corners abutting the building, make a horizontal

cut in the roof material. Fold material down. Follow
Figure 12.

7. Complete installation of termination bars and
caulking, following pages 4 and 5. Install the
termination bars on the short sides first.


Condition B: Short side of Bally structure's membrane

roof abuts existing building.
1. The length of your roofing material will be 6" longer

than the length shown in the chart on page 2. These 6
inches are added to the reverse tab side. See Figure

14. Note: Tabs will run parallel to building wall. (See

Figure 15) Space between building wall and existing
building must be flashed first. Perforated material is

recommended to allow circulation if Bally building is a

cooler or freezer. (See Figure 10)

2. Included with your membrane roof will be two

outside corner pieces (See Figure 11) Install these

corners before installing your membrane roof. Caulk

first. (See Figures 11 and 12)

3. Use 6" for your chalk-line dimension. Your Installation

must start next to the existing building wall.

4. Now follow the instructions on pages 4 and 5 for the

remainder of the installation. Hold overlap on outer
sides as indicated in the chart on page two. Complete
installation of roofing material on ceiling panels.

5. Flash roof material to building wall following Figure

13.

6. At the corners abutting the building, make a

horizontal cut in the roof material. (Follow Figure 12)

7. Following instructions on pages 4 and 5, complete

installation of termination bars and caulking.

Condition C: one short and one long side of Bally

structure's membrane roof abut existing building.

1. The length and width of your roofing material will be

6" greater than dimensions shown in the chart on
page 2. Note: Tabs should run parallel to short

dimension. (See Figure 16) Space between building
wall and existing building must be flashed first.

Perforated material is recommended to allow
circulation if Bally building is a cooler or freezer. (See
Figure 10)

2. Fold the membrane material back before rolling up

roof material. See Figure 16.

3. Included with your membrane roof will be two

outside corner pieces (See Figure 11) Install these
corners before installing your membrane roof. Caulk

first. (See Figures 11 and 12)

4. Use 6" for your chalk-line dimension. Your Installation

must start next to the short wall of the existing

building.

5. Find overhang column in chart on page two. Hold this

dimension along open end of Bally building. See

Figure 16.

6. Attach membrane roof to Bally ceiling panels, using

technique explained on pages 4 and 5.

7. Flash roof material to building wall following Figure

13. See Figure 17 for method of folding corner.

8. At corners abutting the building, make a horizontal

cut in the roof material. Fold material down. Follow
Figure 12.

9. Complete installation of termination bars and

caulking, following pages 4 and 5.

Advertising