Electrical view, Piping view, Thermostatic expansion valve selection chart – Bally Refrigerated Boxes BB Medium Profile Unit Coolers User Manual
Page 6: Electrical view piping view
ELECTRICAL VIEW PIPING VIEW
SUCTION
EXTERNAL
TX VALVE
TERMINAL BLOCK
CONN.
EQUALIZER CONN.
CONN.
THERMOSTATIC EXPANSION VALVE
SELECTION CHART FOR +35
°°F ROOMS AND UP
ALCO VALVE MODEL*
SPORLAN VALVE MODEL
MODEL
T.D.
CAPACITY
MBH
REFRIGERANT
R22
REFRIGERANT
R502/404A/507
REFRIGERANT
R134a
REFRIGERANT
R22
REFRIGERANT
R502/404A/507
REFRIGERANT
R12/R134a
120A
10
15
20
30
HFES-2-HC
HFES-2 1/2-HC
HFES-1 1/2-RC
HFES-2-RC
HFES-1 1/2-MC
HFES-2 1/2-MC
EGVE-1 1/2-C
EGVE-3-C
EGSE-1 1/2-C
EGSE-2-C
EGJE-1 1/2-C
EGJE-2-C
125A
10
15
25
37.5
HFES-2-HC
HFES-3-HC
HFES-2-RC
HFES-3 1/2-RC
HFES-1 3/4-MC
HFES-4-MC
EGVE-2-C
EGVE-3-C
EGSE-2-C
SSE-3-C
EGJE-1 1/2-C
SJE-2 1/2-C
131A
10
15
31
46.5
HFES-2 1/2-HC
HFES-5 1/2-HC
HFES-3 1/2-RC
HFES-3 1/2-RC
HFES-2 1/2-MC
HFES-4-MC
EGVE-3-C
EGVE-3-C
EGSE-2-C
SSE-4-C
EGJE-2-C
SJE-3-C
239A
10
15
39
58.5
HFES-3-HC
HFES-5 1/2-HC
HFES-3 1/2-RC
HFES-5-RC
HFES-4-MC
HFES-4-MC
EGVE-3-C
SVE-4-C
SSE-3-C
SSE-4-C
SJE-2 1/2-C
SJE-5-C
247A
10
15
47
70.5
HFES-5 1/2-HC
HFES-5 1/2-HC
HFES-3 1/2-RC
HFES-5-RC
HFES-4-MC
HFES-6-MC
EGVE-3-C
SVE-5-C
SSE-4-C
SSE-6-C
SJE-3-C
SJE-6-C
254A
10
15
54
81
HFES-5 1/2-HC
HFES-8-HC
HFES-5-RC
HFES-7-RC
HFES-4-MC
HFES-6-MC
SVE-4-C
SVE-8-C
SSE-4-C
SSE-7-C
SJE-5-C
SJE-6-C
263A
10
15
63
94.5
HFES-5 1/2-HC
HFES-8-HC
HFES-5-RC
HFES-10-RC
HFES-4-MC
HFES-7 1/2-MC
SVE-4-C
SVE-8-C
SSE-4-C
SSE-7-C
SJE-5-C
OJE-6-C
374A
10
15
74
111
HFES-5 1/2-HC
HFES-10-HC
HFES-7-RC
HFES-10-RC
HFES-6-MC
HFES-7 1/2-MC
SVE-5-C
SVE-8-C
SSE-6-C
OSE-9-C
OJE-9-C
OJE-12-C
383A
10
15
83
124.5
HFES-8-HC
HFES-10-HC
HFES-7-RC
HFES-10-RC
HFES-6-MC
HFES-11-MC
SVE-8-C
SVE-10-C
SSE-7-C
OSE-9-C
SJE-6-C
OJE-9-C
393A
10
15
93
139.5
HFES-8-HC
HFES-10-HC
HFES-10-RC
TRAE-12-RC
HFES-7 1/2-MC
HFES-11-MC
SVE-8-C
SVE-10-C
OSE-7-C
OSE-12-C
OJE-6-C
OJE-9-C
* Where available use the HFESC series valve which includes sweat fittings with a removable/cleanable inlet screen.
Note: Above Selections are based on 100
°
F Entering Liquid Temperature.
VENTURI - FLO distributor does not require the selection or use of distributor nozzles,
- 6 -