AD-4

AIR DRYER TROUBLESHOOTING CHART (Continued)

D. Excessive bends in

discharge line (water
collects and freezes).

E. Refer to Symptom 4,

causes E & F.

SYMPTOMS

CAUSE

REMEDY

F. Governor malfunction.

Missing or restricted
governor control line
installation.

F. Test governor operation and/or inspect the

control line leading from the governor UNL
(unloader) port to the air dryer control port.

5. Constant exhaust of air

at air dryer purge valve
exhaust. (Charge
mode.)

A. Air dryer purge valve

leaking excessively.

B. Compressor fails to

unload (stop
compressing air) and air
dryer purge exhaust
makes “sputtering” or
“popping” sound.

C. Purge control line

connected to reservoir or
exhaust port of governor.

D. Purge valve frozen open -

malfunctioning heater
and thermostat, wiring,
blown fuse.

A. With compressor loaded, apply soap solution

on purge valve exhaust, to test for excessive
leakage. Repair purge valve as necessary.

B. Confirm failure to unload by increasing &

decreasing engine RPM and noting change in
the rate of leakage and intensity of
accompanying leakage sound. Repair/replace
compressor unloaders.

C. Purge control line must be connected to

unloader port of governor.

D. Test heater and thermostat as described in

Preventative Maintenance Section.

E. See Symptom #1.

E. Excessive system

leakage.

F. Purge valve stays open -

supply air leaks to
control side.

F. Repair purge valve and housing.

6. Can not build system air

pressure.

A. Inlet and outlet air

connections reversed.

B. Check valve between air

dryer and first reservoir.

C. Kinked or blocked

(plugged) discharge line.

A. Connect compressor discharge to air dryer

supply port. Reconnect lines properly.

B. Test check valve for proper operation. Repair or

replace as necessary.

C. Check to determine if air passes through

discharge line. Check for kinks, bends,
excessive carbon deposits, or ice blockage.

D. Discharge line should be constantly sloping from

compressor to air dryer with as few bends as
possible.

E. Refer to Symptom #4, Remedies E & F.

7. Air dryer does not purge

or exhaust air.

A. Missing, broken, kinked,

frozen, plugged or
disconnected purge
control line.

A. Inspect control line from governor UNL (unloader)

port to control port of air dryer. Test to determine
air flows through purge control line when
compressor unloaded. Check for undrilled
fittings. (See Symptom #4, Remedy C.)

B. After determining air reaches purge valve

(Remedy A above), repair purge valve.

C. Refer to Remedies B, E, G for Symptom #4.

B. Faulty air dryer purge

valve.

C. See Causes, B, E, G for

Symptom #4.