on to the relay portion of the valve. The emergency function
of the valve automatically applies full trailer reservoir air
pressure to the trailer chambers when the trailer supply
pressure falls below a predetermined minimum value.

The RE-6

/RE-6NC

relay emergency valve may be

fl ange or reservoir mounted. Ports are clearly identifi ed for
delivery, service, emergency (supply) and reservoir lines.

RE-6NC

VALVE DESCRIPTION

The RE-6NC

valve is a special non-charging relay

emergency valve. It is used on dollies to comply with
FMVSS 121. The RE-6NC

valve eliminates the need for

a protected reservoir to provide the release air for the trailer
spring brakes when the following requirements are met:

- The trailer supply line must be 70 psi minimum with any
leakage-type service system failure.

- The parking brake must not drag at trailer supply line
pressures above 70 psi.

The relay function of the RE-6NC

valve is identical to that

of the RE-6

valve, serving the dolly or trailer system as

a remote controlled brake valve. The emergency function
of the valve automatically applies full trailer reservoir air
pressure to the trailer or dolly chambers when the trailer
supply pressure falls below a predetermined minimum
value. The major difference between the RE-6

and the

RE-6NC

valve is that the RE-6NC

valve allows supply

pressure (initial charge) to release the spring brakes before
the dolly or trailer reservoir(s) is fi lled.

RE-6

& RE-6NC

VALVE SYSTEM

CONFIGURATION

In the RE-6

valve dolly system, the supply air fl ows to the RE-

6

valve, passes through the valve, holding the chambers in

the apply position while simultaneously fi lling the reservoir.
In the RE-6NC

valve dolly system, reservoir air is not

supplied through the RE-6NC

valve, as it is in the RE-6

valve system. The supply air fl ows to the RE-6NC

valve,

acts upon the emergency piston, pushing the emergency
piston toward the inlet / exhaust valve seat. System
pressure in the chambers and reservoir are still at 0 psi in the
RE-6NC

valve system, allowing for faster trailer pull-away.

In the RE-6NC

valve system, air is also fl owing to the

PR-3

valve, which will allow the air to fl ow on to the

reservoir at a pressure setting of about 70 psi. The major
difference between the RE-6

valve and the RE-6NC

valve is that the RE-6NC

valve does not require the

system to charge the reservoir to a predetermined psi
before drive away is allowed. Refer to Figure 3.

CHARGING THE RE-6

& RE-6NC

VALVES

BELOW 45 PSI

When the air brake system is charging below 45 psi,
emergency supply air enters the RE-6

and RE-6NC

valves emergency port. In the RE-6

valve the air acts on

the check valve and the emergency piston. In the RE-6NC

valve the air acts on the emergency piston, because there
is no check valve present. This allows for faster drive away
(reference FMVSS 121 regulation). In the RE-6

valve, the

supply air is forced past the check valve, fl owing through
the emergency piston shoulder and past the inlet / exhaust
valve. The air fl ows to the upper portion of the valve,
underneath the relay piston and out to the service brake
chambers while simultaneously fi lling the reservoir with the
same air that is passing through the emergency piston. In the
RE-6NC

valve, air is only acting upon the emergency

piston. The check valve is not present. In replacement
of the check valve, the RE-6NC

valve uses a reservoir

control valve (the Bendix

®

PR-3

valve), to allow the

reservoir to be fi lled. The PR-3

valve is totally separate

from the RE-6NC

valve, but is necessary for proper

operation of the RE-6NC

valve. Air acts on the PR-3

valve piston, but will not fl ow on to the reservoir until about
70 psi. Refer to Figure 4.

RE-6

Relay Valves

RE-6NC

Relay Valves

RESERVOIR

45 PSI

CHAMBERS

45 PSI

EMERGENCY

SUPPLY

45 PSI

0 PSI

0 PSI

45 PSI

FIGURE 4 RE-6

& RE-6NC

RELAY VALVES CHARGING

BELOW 45 PSI

Advertising