Bendix Commercial Vehicle Systems QR-1C DBL CHECK QUICK RELEASE VALVE User Manual

Description, Bendix, Qr-1c

Advertising
background image

1

FIGURE A

SD-03-904

DESCRIPTION

The Bendix

®

QR-1C

is a dual function valve. The valve’s

primary function is to serve the emergency side of a spring
brake actuator as a quick release valve. In addition, it
functions as an anti-compound device. The double check
valve prevents a service and emergency brake application
from occurring simultaneously.
The QR-1C

valve is generally mounted on the axle and

serves two spring brake actuators. The air connections to
the QR-1C

valve are as follows:

1. QR-1C

valve delivery port (2) connected to emergency

port of spring brake.

2. QR-1C

valve balance port (1) connected to delivery of

brake valve or relay valve. NOTE: If relay valve is installed
on vehicle, it should be connected to the delivery side
(not service or signal side).

3. QR-1C

valve supply port (1) connected to delivery of

park control valve.

In its standard configuration the valve is designed to deliver
within 1 psi of control pressure. However, for special
applications the valve is available with greater differential
pressure or zero hysteresis. QR-1C

valves also come with

optional noise reducing foam crosses or silencers. Some
QR-1C

valves can also come with biased double check

valves. These double check valves contain a beaded seat
cap nut (Figure B). The bias design minimizes low differential
leakage.

Bendix

®

QR-1C

Double Check and Quick Release Valve

Mounting Holes

Delivery (2)

Supply
Port(1)

Body

Quick Release

Diaphragm

Delivery

Sealing Ring

Exhaust

Cover

Sealing Ring

Double Check

Diaphragm

Balance Port(1)

Cap Nut

Beaded
(Biased) Seat

Non-Beaded

Identification

Mark

FIGURE B