Symptom:

What it may indicate:

What you should do:

26

10.0 Air charging
system doesn’t
build air.

(a) Governor malfunction*.

(b) Restricted discharge line.

(c) Air dryer heater malfunction:

exhaust port frozen open.

(d) Compressor malfunction.

Go to Test 4 on page 30.

See 9.0(f).

Replace air dryer heater.

Replace the compressor only after making

certain the preceding conditions do not
exist.

11.0 Compressor
safety valve
releases air
(Compressor
builds too much
air).

(a) Restricted discharge line.

(b) Downstream air brake system check

valves or lines may be blocked or
damaged.

(c) Air dryer lines incorrectly installed.

(d) Compressor safety valve malfunc-

tion.

(e) Compressor unloader mechanism

malfunction.

(f) Governor malfunction.

If discharge line is restricted:

By more than 1/16" carbon build up,

replace the discharge line (see Table A,
column 2, on page 18 for recommended
size) and go to Test 3 on page 29.

By other restrictions (e.g. kinks).

Replace the discharge line. See Table A,
column 2, on page 18 for recommended
size.

The discharge line must maintain a con-

stant slope down from the compressor to
the air dryer inlet fi tting to avoid low points
where ice may form and block the fl ow.
If, instead, ice blockages occur at the air
dryer inlet, insulation may be added here,
or if the inlet fi tting is a typical 90 degree
fitting, it may be changed to a straight
or 45 degree fi tting. For more informa-
tion on how to help prevent discharge
line freeze-ups, see Bendix Bulletins
TCH-08-21 and TCH-08-22 (Appendix B).
Shorter discharge line lengths or insulation
may be required in cold climates.

Inspect air lines and verify check valves are

operating properly.

Ensure discharge line is installed into the

inlet of the air dryer and delivery is routed
to the service reservoir.

Verify relief pressure is 250 psi. Replace if

defective.

Go to Test 6 on page 30.

Go to Test 4 on page 30.

Damaged
discharge
line shown.

* Note: For the Bendix

®

DuraFlo

596

air compressor, not only

the governor, but also the SV-1

synchro valve used would

need to be tested. See Bulletin TCH-001-048.