20

TROUBLESHOOTING

SECTION VII

TESTING FOR THE REAR (M-12

) MODULATOR

Is resistance in range?

Replace the M-12

modulator

solenoid assembly

NO

Are any red LEDs

illuminated?

Repeat the “Initial

Start-up Procedure”

Are same red LEDs

illuminated?

YES

NO

Go to Section IV

“Inspection for Illuminated

Red LEDs”

YES

NO

RESETTING

EC-14

CONTROLLER

MAGNET

HERE

YES

START HERE

Turn the ignition off. Separate the EC-14

controller

from the M-12

modulator. Disconnect the four pin

connector between the two components and test

resistance on the modulator connector.

Black to black: ........................................ 9 to 12 Ohms
White to white: ....................................... 9 to 12 Ohms

Reconnect EC-14

controller to M-12

modulator. Turn ignition on and pass magnet

over “RESET” on EC-14

controller and

remove. Note reaction of red LEDs

Replace EC-14

controller.

Repeat the “Initial Start-up

Procedure.”

WHITE

WHITE

BLACK

BLACK

M-12

MODULATOR

WIRE HARNESS

CONNECTOR