Operation – Bendix Commercial Vehicle Systems TP-3DC TRACTOR PROTECTION VLV 6/07 User Manual

Page 2

Advertising
background image

2

FIGURE 3 - PARTIAL AIR BRAKE SYSTEM SCHEMATIC WITH TP-3DC

TRACTOR PROTECTION VALVE WITH DOUBLE

CHECK

TRACT

CONT

TRLR

SUP

TRAC

CONT

STP LT

SW

TRLR CNTL

FIGURE 2 - TP-3DC

TRACTOR PROTECTION VALVE WITH

DOUBLE CHECK SECTIONAL VIEW

TRACTOR CONTROL

(PRIMARY)

TRACTOR

CONTROL

(SECONDARY)

AUXILIARY SUPPLY

TRACTOR

SUPPLY

STOP LIGHT

SWITCH

PLUNGER

TRAILER

SUPPLY

CHECK VALVE

SPRING

CHECK VALVE

TRAILER

CONTROL

VALVE SPRING

GUIDE

DIAPHRAGM

TRAILER

SUPPLY VALVE

TRAILER

CONTROL VALVE

DOUBLE CHECK VALVE

(TO TRACTOR

SPRING BRAKES)

AUX

SUP

TRAC

SUP

OPERATION

INITIAL CHARGE

As shown in Figure 4, during initial charge air pressure
enters the TP-3DC

tractor supply port (TRAC SUP). In

addition to passing through the TP-3DC

valve to and out

the trailer and auxiliary supply lines, supply air moves the
plunger, against valve spring pressure, into contact with
the guide. With approximately 45 psi at the tractor supply
port, the inlet valve opens. The TP-3DC

valve is now in the

normal “run” mode, ready to receive and deliver a service
brake application from the foot valve or hand valve.

SERVICE BRAKE APPLICATION

Figure 5 shows a normal service brake application. Supply
air holds the valve open, and the TP-3DC

valve receives

service air from the primary and secondary service
circuits on the tractor. The greater pressure of the two (the
secondary service circuit double check valve delivers the
greater of foot valve secondary delivery and trailer hand
control valve delivery) will cause the TP-3DC

valve's

internal check valve diaphragm to seal the port with the
lower pressure. The higher pressure will then fl ow out the
open inlet to the trailer control line. Figure 5 shows an
application with primary service air as the greater pressure.
Note that service air pressure also activates the stop light
switch, and it fl ows to the single check valve. However, with
supply pressure acting on the opposite side of the single
check valve, the valve remains closed.

Embossed I.D. Thread Size

TRAC SUP

1/4"-18 NPT

AUX SUP

1/4"-18 NPT

TRACT CONT

3/8"-18 NPT

TRAC CONT

3/8"-18 NPT

STP LT SW

1/4"-18 NPT

TRLR SUP

1/2"-14 NPT

TRLR CNTL

1/2"-14 NPT