Troubleshooting – Bendix Commercial Vehicle Systems EC-13 TRAILER ANTILOCK CONTROL 8/07 User Manual

Page 15

Advertising
background image

15

SAME RED LED’s

ILLUMINATED?

NO

YES

YES

ARE ANY RED LED’s

ILLUMINATED?

INSPECT CONNECTOR AND RECONNECT

TO EC-13

CONTROLLER. TURN IGNITION

ON AND PASS MAGNET OVER “RESET” ON

EC-13

CONTROLLER. REMOVE MAGNET

AND NOTE REACTION OF RED LEDS.

ARE RESISTANCE
VALUES CORRECT?

YES

GO TO SECTION V B AND
CONTINUE TESTING

NO

REPEAT “INITIAL START-UP

PROCEDURE”. IF TESTING HAS

RETURNED TO THIS STEP TWICE -

REPLACE THE EC-13

CONTROLLER.

REPLACE EC-13

CONTROLLER

NO

GO TO SECTION III

“INSPECTION FOR

ILLUMINATED LEDS”

AND RETEST.

IF FAILURE PERSISTS,

REPLACE THE EC-13

CONTROLLER.

PROBE CONNECTOR WITH VOLT/OHM METER AND NOTE THAT

PROPER RESISTANCE VALUES ARE OBTAINED FOR

MODULATOR BEING TESTED. RESISTANCE VALUES HERE FOR A

BENDIX

®

M-12

MODULATOR.

FRONT MODULATOR

HOLD TO SOURCE (2G TO 1G):

READ 9 TO 12 OHMS

EXHAUST TO SOURCE (2F TO 1G):

READ 9 TO 12 OHMS

EXHAUST TO HOLD (2F TO 2G):

READ 18 TO 24 OHMS

SOURCE TO POWER (1G TO 1K, 2K):

NO CONTINUITY

SOURCE TO GROUND (1G TO 1A, 2A):

NO CONTINUITY

REAR MODULATOR

HOLD TO SOURCE (1C TO 1D):

READ 9 TO 12 OHMS

EXHAUST TO SOURCE (1B TO 1D):

READ 9 TO 12 OHMS

EXHAUST TO HOLD (1B TO 1C):

READ 18 TO 24 OHMS

SOURCE TO POWER (1D TO 1K, 2K):

NO CONTINUITY

SOURCE TO GROUND (1D TO 1A, 2A):

NO CONTINUITY

TURN IGNITION OFF. DISCONNECT

30 PIN WIRE HARNESS CONNECTOR

FROM EC-13

CONTROLLER.

START HERE

WIRE HARNESS CONNECTOR

2F

EXHAUST

2G

HOLD

1A, 2A

GROUND

1K, 2K

POWER

1G

SOURCE

1C

HOLD

1B

EXHAUST

1D

SOURCE

MAGNET HERE

RESETTING

EC-13

CONTROLLER

Troubleshooting

SECTION V PART A

TESTING THE MODULATOR