Bendix Commercial Vehicle Systems R-12DC DBL CHECK RELAY VALVE 3/07 User Manual

Bendix, R-12dc, Relay valve with biased double check

Advertising
background image

1

Bendix

®

R-12DC

Relay Valve with Biased Double Check

DESCRIPTION

The relay valve in an air brake system functions as a relay
station to speed up the application and release of the
brakes. The valve is normally mounted at the rear of the
vehicle in proximity to the chambers it serves. The valve
operates as a remote controlled brake valve that delivers

FIGURE 1 - EXTERIOR VIEWS

EXTERIOR R-12DC

VALVE

(MODEL WITH 2 HORIZONTAL PORTS)

PRIMARY

SERVICE

DELIVERY

SUPPLY (2)

SD-03-1068

SECONDARY

SERVICE

EXTERIOR

R-12DC

VALVE

(MODEL WITH

4 VERTICAL

DELIVERY PORTS)

EXTERIOR

R-12DC

VALVE

(MODEL WITH 2

HORIZONTAL AND 2

VERTICAL DELIVERY

PORTS)

PRIMARY

SERVICE

PORT

FIGURE 2 - R-12DC

RELAY VALVE WITH BIASED DOUBLE CHECK SECTIONAL VIEW

RELAY

PISTON

VALVE

RETAINER

EXHAUST

SEAT

RETAINING

RING

EXHAUST

PORT

SECONDARY

SERVICE PORT

DOUBLE CHECK

DIAPHRAGM

GUIDE

SPRING

CAP SCREW

SEALING

RING

COVER

RELAY

PISTON

O-RING

SPRING

O-RINGS

INLET

EXHAUST

VALVE

or releases air to the chambers in response to the control
air delivered to it from the foot brake valve.

The R-12DC

relay valves are designed for either reservoir

or frame mounting. (See Figure 1). For ease of servicing,
the inlet/exhaust valve can be replaced without the need for
line removal.

Advertising