Power and ground – Bendix Commercial Vehicle Systems MC-30 TRAILER ABS CONTROLLER User Manual

Page 4

Advertising
background image

4

Auxiliary I/O Connector

An optional auxiliary connector provides a connection to
the MC-30

controller auxiliary feature I/O pins. The fi ve

auxiliary ground-switch inputs and two auxiliary outputs can
be activated and confi gured with a diagnostic tool.

FIGURE 5 - MC-30

CONTROLLER PIGTAIL HARNESS (4S/2M WITH DIAGNOSTIC AND AUXILIARY CONNECTORS

SHOWN)

30-Pin ECU

Connector

8-Pin Auxiliary

(AUX)

3-Pin Modulator 2

(MOD2)

3-Pin Modulator 1

(MOD 1)

4-Pin Diagnostic

(DIAG)

5-Pin Power and

Indicator Lamp

(PWR/WL)

2-Pin Wheel

Speed Sensors

ECU Connector Jackscrew

(Tighten to 15-20 in. lbs.)

Left Rear

(LFT RER)

Right Rear
(RHT RER)

Left Front
(LFT FRT)

Right Front

(RHT FRT)

FIGURE 6 - REMOTE MODULATOR HARNESS (MOD2)

Modulator 2

(MOD2)

To

Pigtail

FIGURE 7 - REMOTE DIAGNOSTIC HARNESS

To

Pigtail

To Diagnostic

Tool

POWER AND GROUND

Trailer electrical power is supplied to the MC-30

controller

from the ignition and brake light circuits. Note: The MC-30

controller may not function properly when powered with a
battery charger. See Chart 2.