Bendix Commercial Vehicle Systems GEN 5 ABS User Manual

Page 10

Advertising
background image

10

FIGURE 12 - ABS/ATC Hold

FIGURE 10 - Normal Apply and ABS/ATC Apply

FIGURE 13 - ABS/ATC Release

FIGURE 11 - Normal Release

Modulator Valve Operation Modes

1. Apply–Air flows straight through valve. Hold diaphragm

is vented to allow air flow. Inlet pressure feeds behind
release diaphragm to block the exhaust port. No
solenoids are activated.

2. Normal Release–With quick release function, hold

diaphragm is vented and there is no pressure at the
inlet port. Air is allowed to flow from outlet to inlet. Since
release diaphragm is not pressurized, air also flows out
the exhaust port. No solenoids are activated.

Outlet

Solenoid

Exhaust

Inlet

Vents

Release
Diaphragm

Hold
Diaphragm

Outlet

Exhaust

Inlet

Zero

Pressure

Outlet

Exhaust

Inlet

Outlet

Exhaust

Inlet

3. ABS/ATC Hold–The hold solenoid is activated. Both

diaphragms are pressurized. No air flows through the
valve.

4. ABS/ATC Release–Both solenoids are activated. The

hold diaphragm is pressurized, blocking the inlet air.
The release diaphragm is vented, allowing air to flow
from the outlet port back through the exhaust port.