CHARGING SPRING BRAKE ACTUATORS BELOW
107 PSI (FIGURE 5)

With the air brake system charged and the parking brakes
released (by pushing the dash valve button in), air enters
the park control port. This opens the Bendix

®

SR-7

®

valve

to supply air pressure to the spring brake chambers. As
illustrated, air pressure in the chambers is below 107 psi
(nominally).

CHARGING SPRING BRAKE ACTUATORS ABOVE
107 PSI (FIGURE 6)

Once the SR-7

®

valve delivery pressure reaches 107 psi

(nominal), the inlet and exhaust are closed (valve lap
position). This maintains the spring brake hold-off pressure
at 107 psi (nominal).

BALANCE PORT

SECONDARY RESERVOIR

CONSTANT PRESSURE

FIGURE 5 - CHARGING LESS THAN 107 PSI

CONTROL LINE PRESSURE

DELIVERY TO SPRING BRAKES

INLET / EXHAUST VALVE OPEN

CONTROL PORT

FIGURE 6 - CHARGING GREATER THAN 107 PSI

INLET / EXHAUST VALVE SEATED

CONTROL LINE PRESSURE

DELIVERY TO SPRING BRAKES

BALANCE PORT

CONTROL PORT

SECONDARY RESERVOIR

CONSTANT PRESSURE