Removal, Leakage checks – Bendix Commercial Vehicle Systems SMS-9700 ACCESSORY SOLENOID MANIFOL User Manual

Page 3

Advertising
background image

3

REMOVAL

1. Prior to removing a solenoid, apply the parking brakes

and drain all the vehicle reservoirs. Refer to the General
Safety Guidelines in this manual before performing any
service.

2. Identify, mark, and disconnect all air lines to the

solenoid. Push-to-connect fi ttings require the collar
to be pressed toward the valve body before the nylon
line can be pulled. Note that the braided hose version
(Arctic) uses compression fi ttings.

LEAKAGE CHECKS

With the air system fully charged, coat the exhaust ports
of the solenoid with a soap solution. A 1-inch bubble in
three (3) seconds is permitted (175 SCCM).

If the solenoid does not function as described above, or if
leakage is excessive, it is recommended that it be replaced
with a genuine Bendix

®

service replacement.

FIGURE 3 - SERVICING THE BENDIX

®

SMS-9700

SOLENOID MANIFOLD

END CAP

LOCKING TAB

LOCKING TAB

O-RING - 2

BODY BOLT

NON-REMOVABLE

FASTENER

COMMON RAIL

SUPPLY PORT

SUPPLY END CAP CONFIGURATIONS -

THESE END CAPS ARE USED WHEN

A 3/8" NYLON AIR LINE IS USED TO

SUPPLY THE MANIFOLD

STRAIGHT -

3/8" PTC

90° ELBOW

3/8" PTC

Advertising