AD-9

®

and AD-9

®

IPC (Integrated PuraGuard

®

Coalescing)

Air Dryers

EXTENDED

PURGE

STANDARD

DESCRIPTION

The function of the Bendix

®

AD-9

®

and AD-9

®

IPC Integrated

PuraGuard

®

Coalescing air dryers is to collect and remove

air system contaminants in solid, liquid, and vapor form
before they enter the brake system. They provide clean, dry
air to the components of the brake system which increases
the life of the system and reduces maintenance costs. Daily
manual draining of the reservoirs is eliminated.

The Bendix AD-9 and AD-9 IPC Integrated PuraGuard
Coalescing air dryers consists of a desiccant cartridge
and a die cast aluminum end cover secured to a cylindrical
steel outer shell with eight cap screws and nuts. The end
cover contains a check valve assembly, a safety valve,
three threaded air connections, and the purge valve
housing assembly. The removable purge valve housing
assembly incorporates a purge valve mechanism and a
turbocharger cut-off feature that is designed to prevent loss

OUTER

SHELL

SUPPLY

PORT

WIRING HARNESS

CONNECTION

DELIVERY PORT

CHECK

VALVE

ASSEMBLY

END COVER

CONTROL

PORT

FIGURE 1 - BENDIX

®

AD-9

®

AND AD-9

®

IPC AIR DRYER MODELS

IPC AIR DRYER LABEL

SAFETY VALVE

PURGE VALVE

END COVER

Advertising