DELIVERY CHECK VALVE CLEANING PROCEDURE
(

Note: This is only required if system pressure does not

build after temporary bypass is completed.)
Refer to Figure 6 throughout this procedure. Depressurize

the air brake system following the General Safety

Guidelines outlined on page 2 in this document. Also,

always depressurize the air dryer purge reservoir before

servicing the air dryer.
This procedure does not require removal of the Bendix

®

AD-IS

®

air dryer from the vehicle.

1. Remove the line from governor and mark for easy

reinstallation.

2. Remove the bolts attaching the governor to the AD-IS

®

air dryer and retain for reassembly.

3. Remove the governor from the air dryer. Be aware that

a short puff of trapped air may vent when the governor is

removed. Retain the governor gasket for reassembly if

a new governor gasket is not available. Remove and

retain the o-ring from the adapter.

4. The spring/delivery check valve can now be removed.

A second delivery check valve is located in the dryer

without a governor. This check valve is located behind

a hex head plug near the control line from the Bendix

®

EverFlow

®

electronic module to the air dryer. Carefully

remove the hex plug and follow the instructions that

follow.

5. Remove and retain the o-ring from the check valve

body.

CLEANING & INSPECTION
Consult the service data sheet for the dryer used in your

AD-IS

®

EverFlow

®

assembly. The service data sheet

contains information useful for maintenance and service

of the air dryers.

CLEANING & INSPECTION
1. Use a suitable solvent to clean all metal parts, and

use a cotton swab to clean the bore (Note: Do not use

abrasives or tools to clean the bore: any scratches

caused may necessitate replacing the AD-IS

air

dryer and reservoir system.) Superficial external

corrosion and/or pitting is acceptable.

2. Clean the o-rings with a clean dry cloth. Do not use

solvents.

3. Inspect for physical damage to the bore and the check

valve seat. If the bore is damaged (by scratches

etc., that would prevent the delivery check valve from

seating), replace the AD-IS air dryer.

4. Inspect the delivery check valve, o-rings, etc. for wear or

damage. Replace, if necessary, using the check valve

replacement kit available at any authorized Bendix parts

outlets.

5. Inspect all air line fittings for corrosion and replace as

necessary.

FIGURE 6 -

BENDIX

®

AD-IS

®

AIR DRYER DELIVERY CHECK VALVE

GOVERNOR GASKET

(SPECIAL GASKET,

SEE NOTE 6)

GOVERNOR

(NON-ADJUSTABLE,

130 PSI CUT-OUT)

BOLTS

ADAPTER

LARGE

O-RING

SPRING

CHECK VALVE

BODY

SMALL

O-RING

Advertising