5

O-RING IDENTIFICATION

Key

I.D.

O.D.

W

2

3.487

3.693

0.103

3

3.234

3.512

9

1.424

1.630

10

0.862

1.068

14

0.255

0.435

0.066

Key No.

Description

1 . . . . . . Valve Cover
2 . . . . . . O-ring
3 . . . . . . O-ring
4 . . . . . . Relay Piston
5 . . . . . . Valve Body
6 . . . . . . Inlet & Exhaust Valve
7 . . . . . . Valve Retainer
8 . . . . . . Spring
9 . . . . . . O-ring
10. . . . . . O-ring
11. . . . . . Exhaust Cover
12. . . . . . Retaining Ring
13. . . . . . Differential Spring (If Used)
14. . . . . . Sealing O-ring

FIGURE 7 - ATR-6

EXPLODED VIEW AND O-RING IDENTIFICATION

DIFFERENTIAL SPRING

(CONTROLS CRACK PRESSURE*)

(Not used for most models.

See box below.)

13

11

CAP SCREW

1

5

6

2

4

3

12

10

9

8

7

VERTICAL

DELIVERY

PORTS

SUPPLY

PORT

HORIZONTAL

DELIVERY

PORTS

TRACTION

SOLENOID

See Below for O-ring Identifi cation Chart

Washer Identifying

Crack Pressure

SECTIONAL SIDE

VIEW SHOWING

HOW AN O-RING IS

MEASURED.

I.D."

W

O.D."

DIFFERENTIAL SPRINGS

*Crack Pressure is the amount of control pressure required by
the valve to initiate air delivery. For Crack Pressures other than
4 psi, a differential spring is used in the assembly to produce
the required valve response.

(Models designed to have a 4 psi Crack Pressure do not require a
differential spring.)

14