Figure 10 Manual Scaling Single Frequency Model

Sweep Type-Single Hold vs. Continuous

Continuous sweep continually sweeps the selected fre-

quency band updating the measured value with each

sweep. An asterisk (*) is blinking on the left side of the

display to indicate sweep rate. The single hold mode

will freeze a trace on the display and hold is displayed

on the right. Holding a trace is also helpful before sav-

ing the trace, (more about saving traces under that

heading later in this section).

Swept Frequency

Select Frequency Band

There are two options for selecting the frequency band.

The first is simply to enter the start and stop frequen-

cies. The second is to enter a span frequency, which is

the desired width of the band, and a center frequency,

that will be used as the center of the band.
1. Press the MENU key.
2. Press the SWEPT FREQ key.
3. Press the BAND key.
4. Depending on desired method press either Start

Stop MHz or Center MHz:

VSWR

1.0

5.0

1.35

69.00 MHz

Freq

Mhz

Units

Manual

Scale

Auto

Scale

Audio