GENERAL DESCRIPTION

This manual details the installation of an optional
narrowband preselector filter for the TX RX Sys-
tems Tower Top Amplifier. There are nine different
filters available for use with your TTA system. Four
filters operate in the 792 to 806 MHz range and five
filters in the 806 to 824 MHz range. Table 1 lists all
of the narrowband filters available. The narrowband
filter is designed to be added to the TTA systems
RF signal path just after the distribution amplifier in
the MCU. The additional filter will provide a nar-
rower pass window for the MCU.

Figure 1 shows the basic interconnect diagram for
the filter. It is recommended that the filter be
mounted in the same rack and just above the MCU.
The optional filter will require 2 “rack units” of
space.

INSTALLATION KIT

Included in the installation kit are:

1) Panel-mounted narrowband preselector with
mounting plates.

2) 24-inch BNC / N cable.

3) 24-inch SMA / N cable.

4) Required installation screws.

Installation Manual for Optional Narrowband Preselector Filter

Models 89/83F-02-03/06/09/14 and 89-86A-02-03/05/10/15/18

Dist

Amp

Opt

Filter

8-Way

4-Way

8-Way

RF
OUT

RF
OUT

RF IN

From

Tower

Figure 1: Basic interconnect diagram for the optional filter.

Filter

Model

Operating

Range

(MHz)

Bandwidth

(MHz)

89-83F-02-03

792 to 806

3

89-83F-02-06

792 to 806

6

89-83F-02-09

792 to 806

9

89-83F-02-14

792 to 806

14

89-86A-02-03

806 to 824

3

89-86A-02-05

806 to 824

5

89-86A-02-10

806 to 824

10

89-86A-02-15

806 to 824

15

89-86A-02-18

806 to 824

18

Table 1: Optional Narrowband Filters.