Termaline® RF

Coaxial Terminations

Instruction Sheet

Interlock Overtemp. Thermoswitch

Purpose

Usage guidelines for the Bird 8251T Load.

This 8251T load has been equipped with an interlock overtemperature thermoswitch. It will provide a safeguard against damage that
might occur from accidental transmitter power overload or equipment malfunction. Being normally closed, the thermoswitch opens at
a maximum safe load temperature. When connected in series with the transmitter power interlock, it turns off the transmitter power if
the load temperature exceeds a safe level.

This unit has a temperature adjustment screw that has been set from the factory for the maximum allowable operating temperature of
the load.

DO NOT ADJUST

Do not apply more than 10 in

·

lb (1.1N

·

m) torque on terminal nuts. The terminals are rated for 10 A @ 120 VAC and 5 A @ 240

VAC. Check the requirements of the transmitter interlock and make the connections to the appropriate terminals as required.

WARNING

Remove and replace cover while no power is applied to unit.

WARNING

Limit the interlock terminal to the values in the specifications.

CAUTION

Connect interlock before RF operation.

920-2450-129

10/19/2000

Page 1 of 1